3com WX3000 Manuel D’Utilisation

Page de 715
 
2-4 
Displaying and Maintaining RMON 
To do… 
Use the command… 
Remarks 
Display RMON statistics 
display rmon statistics [ interface-type 
interface-number 
unit unit-number 
Display RMON history 
information 
display rmon history [ interface-type 
interface-number
 | unit unit-number 
Display RMON alarm 
information 
display rmon alarm entry-number 
Display extended RMON alarm 
information 
display rmon prialarm 
prialarm-entry-number ] 
Display RMON events 
display rmon event [ event-entry 
Display RMON event logs 
display rmon eventlog [ event-entry ] 
Available in any view
 
RMON Configuration Examples 
Network requirements 
As shown in 
, the Switch to be tested is connected to a remote NMS through the Internet. 
Ensure that the SNMP agents are correctly configured before performing RMON configuration. 
Create an entry in the extended alarm table to monitor the information of statistics on the Ethernet 
port, if the change rate of which exceeds the set threshold, the alarm events will be triggered. 
Figure 2-1 Network diagram for RMON configuration 
Console port
Switch
Internet
Network port
NMS  
 
Configuration procedures 
# Add the statistics entry numbered 1 to take statistics on GigabitEthernet 1/0/1. 
<device> system-view 
[device] interface GigabitEthernet 1/0/1 
[device-GigabitEthernet1/0/1] rmon statistics 1 
[device-GigabitEthernet1/0/1] quit 
# Add the event entries numbered 1 and 2 to the event table, which will be triggered by the following 
extended alarm. 
[device] rmon event 1 log 
[device] rmon event 2 trap 10.21.30.55 
# Add an entry numbered 2 to the extended alarm table to allow the system to calculate the alarm 
variables with the (.1.3.6.1.2.1.16.1.1.1.9.1+.1.3.6.1.2.1.16.1.1.1.10.1) formula to get the numbers of all 
the oversize and undersize packets received by GigabitEthernet 1/0/1 that are in correct data format 
and sample it in every 10 seconds. When the change ratio between samples reaches the rising 
threshold of 50, event 1 is triggered; when the change ratio drops under the falling threshold, event 2 is 
triggered.