Both Failed — Although the resilient link is cor-
rectly configured, both links have failed. This 
could be due to loose connections or cable dam-
age.
Unknown — The network configuration has 
changed and the resilient link pair no longer con-
forms to the rules.
Not Available — The resilient link pair is disabled.
Active Port Main / Standby If a main link does not 
have a higher bandwidth than its standby link, traf-
fic is not automatically switched back to the main 
link when it recovers. Use this field to manually 
switch traffic back to the main link.
Pair Enable Enabled / Disabled Use this field to 
enable or disable the resilient link pair. Before you 
disable a resilient link pair, you must remove 
cabling from the ports to avoid creating loops in 
your network configuration.
Creating a Resilient Link Pair
1
Ensure that the port nominated as the standby port 
is not physically connected to the unit.
2
Ensure both ports have an identical port security 
mode configuration and that they are members of 
the same VLAN. 
3
At the Switch Management screen, select the port 
to be configured as the main port in the link. Select 
the RESILIENCE button at the foot of the screen.
4
Select the standby port from the Standby Links 
Available listbox or enter the port ID in the Standby 
Port ID field.
5
Enable the pair in the Pair Enabled field. Select 
APPLY.
6
Connect the cabling for the standby port.
Deleting a Resilient Link Pair
To delete a resilient link set up on a port, select the 
DELETE button at the foot of the screen. The Port 
Resilience screen closes and the Switch Manage-
ment screen is displayed.