2.3.4 
Installation of Cable Glands 
 
Figure 2-5 
Cable Glands 
Before power and control cables can be 
connected to their respective circuits it will 
first be necessary to fit the cable glands 
supplied. 
Each gland should be located ideally to 
allow for convenient cable runs to the 
terminals located on the Filter and I/O 
boards. 
1.  Using a hammer and a flat-head 
screwdriver as shown in Figure 2-6 
strike the gland plate or ‘knockout’ to 
obtain a clearance for the 25 mm 
cable gland. 
NOTE 
Care must be taken to prevent 
damage to the Terminal Housing, as 
this may affect the IP rating of the 
inverter. 
2.  Remove any sharp edges from the 
gland area and any swarf from the 
terminal housing. 
3.  After the knockout has been removed 
it should be safely discarded and the 
cable glands fitted as shown in Figure 
2-6. 
 
 
A
B
A
B
A
B
1
2
1
2
 
Terminal Housing
 
 
Figure 2-6 
Installation of Cable Gland