Fabric Display Error Messages
TABLE B-2
Fabric Display Messages
cfgadm
: Library error: Failed to get Fabric device
list
The operation to get Fibre Channel device list on a host
port failed. Check the condition field of the host port
from the
cfgadm
listing and diagnose the Fiber
connection of the host port.
cfgadm
: Library error: failed to create device
node:
errno text
The configure operation failed on the device node with
error specified in
errno text
. Check the condition field
of the device from the
cfgadm -la
listing and diagnose
the Fabric connection of the device.
cfgadm: Library error: failed to offline: device
path
Resource
Information
------------------ --------------------------
/dev/dsk/c1t0d0s0 mounted filesystem
"/file-system"
Unmount the file system listed in the error message and
try the
cfgadm
operation again.
Error Message
Corrective Action
Save Operation Failed. Enter IP address and try
again.
Verify network connection
1
to Fabric and retry.
1. Verify network connection to Fabric:
Check that the correct IP address for the Fabric is entered in the Fabric Display. If the address is incorrect, then enter the correct IP
address for the network switch in the Fabric.
Verify that the gateway address is correctly configured on the workstation. If the gateway is incorrect, then configure the correct gate-
way.
Verify that the Fabric is accessible through the network. For example, ping the switch and verify that responses are not being dropped.
If the Fabric is not accessible, then diagnose network the problem, or try to access the Fabric from a different workstation.
Try to access the Fabric from a workstation on the same subnetwork as the Fabric. If the Fabric is manageable on the same subnetwork,
but is not manageable through a network gateway, then examine the network configuration (gateway address, subnet mask, etc.) on
the network switch to verify that it is correct..
Examine the switch itself.  Verify that the switch is powered on, and that the heartbeat LED is blinking
normal ly. If the heartbeat indicates an error, then contact customer support.
Fabric appears to be offline. Hit REFRESH to
verify connection.
Verify network connection
1
to Fabric and retry.
Error Message