Fortinet 5003 Manuel D’Utilisation
![Fortinet](https://files.manualsbrain.com/attachments/1b5d8cfe7b7256038af0fc8f11ea0645b1979a44/common/fit/150/50/6ff6e359203158e39987669188ec093742c96b81ec0664dff6b23b5278e2/brand_logo.png)
FortiSwitch-5003A CLI reference
config
FortiSwitch-5003A and 5003 Fabric and Base Backplane Communications Guide
01-30000-85717-20081205
01-30000-85717-20081205
97
Examples
This example shows how to enable the FortiSwitch-5003A board to listen for heartbeat packets on the
interfaces for chassis slots 6, 8, and 10:
interfaces for chassis slots 6, 8, and 10:
config switch fabric-channel physical-port
edit "slot-6"
set heartbeat enable
next
edit "slot-8"
edit "slot-8"
set heartbeat enable
next
edit "slot-10"
edit "slot-10"
set heartbeat enable
end
This example shows how to bring down the slot-2/1 FortiSwitch-5003A interface. You may need to
bring this interface down to disable communication between fabric channel 1 and fabric channel 2.
config switch fabric-channel physical-port
edit slot-2/1
set status down
end
Related topics
•
•
•
•