Fujitsu XG0448 Manuel D’Utilisation

Page de 49
XG0448 Hardware Guide
Chapter 2 Installation
Requirements for Installation Environment
28
2.1 Requirements for Installation 
Environment
Before installing the switch, please check the following:
Make sure that the switch and all the other options shown in this document are available for installation.
All the cables comply with the specifications of the interface connectors.
Warning
Do not connect cables to interface connectors other than those adaptable to the connector’s 
specifications.
Install the product under the following environmental conditions
2.1.1
Installation Requirements
Caution
Install the product under the following conditions. Using the product outside the required 
environment may cause failure of the product.
Temperature and Humidity Requirements
Power Requirements
Temperature (degrees C)
Humidity (%RH)
Operation
0 to 40
15 to 85
Non-operation
0 to 50
8 to 90
Item
Requirements
Voltage
AC90-264V (*)
Frequency
50Hz / 60Hz  +2%, -4%
Ground
Separate ground wire from air conditioners and building, and D-class grounding with 
ground resistance of 100 
Ω or less.
Electricity
133.1W
Inrush Current
Maximum50A
Ensure installation environment that avoids lowering voltage to power supply 
equipment at the time of power-on due to the inrush current, although there’s no 
impact from the inrush current in normal use.