Avaya 580 Manuel D’Utilisation

Page de 782
User Guide for the Avaya P580 and P882 Multiservice Switches, v6.1
10-1
10
Configuring Redundancy 
Options
Overview
The Avaya Multiservice Switch can be configured with redundancy to 
provide fault tolerance.
For more information about the CLI commands that are mentioned in this 
chapter, see Command Reference Guide for the Avaya P580 and P882 
Multiservice Switches, Software Version 6.1
Supervisor 
Functions
The Avaya Multiservice Switch supervisor module manages the resources 
of the switch, provides access to these resources and supports a number of 
network protocols. These resources include configuration information, 
spanning tree topology, address forwarding tables, routing tables, and 
network statistics. Access is provided to these resources via console CLI 
(command line interface), Web interface, SNMP, and telnet. 
Redundant 
Supervisors
The redundant supervisor module is an auxiliary “standby” supervisor 
module that acts as a fault-tolerant supervisor in the event that the “Active” 
supervisor fails. Once the redundant supervisor is installed, loaded with the 
same software version as the Active supervisor, and synchronized, it is 
ready to act as a redundant or “standby” supervisor. If the Active supervisor 
does fail, the redundant supervisor assumes control of network operation. 
No user intervention is required for the Supervisor module failover. The 
management view is accessible without changing IP or MAC addresses. 
The event is logged and indicated via an SNMP trap. Notification of this 
change is provided by a console message and an event log message.
Multiple Software 
Versions
Up to two software versions can be saved on the Avaya Multiservice Switch 
supervisor module.
Redundant Switch 
Controller and 
Element
The Avaya Multiservice Switch can be configured with a redundant switch 
element module and a redundant switch controller module, for backup of 
both switch fabric components. In the event of a failure in a switch element 
or controller module, the redundant module will take over the function of 
the failed component.