Avaya 580 Manuel D’Utilisation

Page de 782
Document No. 10-300077, Issue 2
10-15
Configuring Redundancy Options
Synchronization Procedure
Web Agent 
Procedure
* Note:  You must synchronize the active and standby supervisor 
modules for the standby (redundant) supervisor to use the same 
configuration as the active supervisor. Save the running 
configuration to the startup configuration so that if the active 
supervisor fails, the current configuration information is not 
lost. Synchronizing the two supervisors copies the startup 
configuration file to the standby supervisor. 
* Note:  The P580 and P882 Supervisor modules must be in the same 
Fabric mode to synchronize.
To synchronize the active and standby supervisor modules: 
1.  Copy the running configuration to the startup configuration. For 
information on how to copy the running configuration to the startup 
configuration, see “
” in 
.” 
2.  In the navigation pane, expand the System > Configuration > CPU 
Redundancy folders, and then click Status/Statistics.
The CPU Redundancy Status Web page is displayed in the content pane. 
See