Avaya C460 Manuel D’Utilisation

Page de 268
Chapter 2        Avaya C460 CLI Commands
Avaya C460 Reference Guide
199
Example to show PoE configuration on I/O module 3:
Output fields:
show powerinline budget
User level: read-only, read-write, admin.
Use the show powerinline budget command to display the PoE budget 
distribution for modules in the switch. The budget assigned for the module includes 
power for PoE ports and power required for module basic PoE operation.
port
(optional)
Number of the port on the module. If you do not specify a 
number, all the ports on the module are shown.
You can also specify a range of ports separated by a dash, for 
example, 4/5-13 for ports 5 to 13 on module 4.
C460-1> show powerinline 3
Port     Inline               Powering
         Operational          Priority
         Status
------   ------------------   ---------
 3/1     Fault                Low
 3/2     Fault                Low
 3/3     Fault                Low
 3/4     Searching            Low
 3/5     Searching            Low
 3/6     Searching            Low
 3/7     Searching            Low
 Field
Description 
Inline operational 
status
• Disabled – Detection process in administratively 
disabled
• Searching – No PD connected
• Delivering power – Valid PD connected and 
power delivered on the port
• Fault – Invalid PD connected
Powering Priority
• Critical
• High
• Low