Chapter 4
Installation and Setup
Avaya P332MF User’s Guide
21
Connecting Stacked Switches
Note:  
The two ends of the Octaplane cable terminate with different connectors. Each 
connector can only be connected to its matching port.
The following cables are used to connect stacked switches:
Short Octaplane cable (X330SC) – ivory-colored, used to connect adjacent 
switches (Catalog No. CB0223) or switches separated by a BUPS unit.
Long/Extra Long Octaplane cable (X330LC/X330L-LC) – ivory-colored, used to 
connect switches from two different physical stacks, or switches separated by a 
BUPS unit (Catalog No. CB0225/CB0270).
Redundant/Long Redundant Octaplane cable (X330RC/X330L-RC) – black, 
used to connect the top and bottom switches of a stack (Catalog No. CB0222/
CB0269).
These are the same cables that are used with all P330 family modules.
To connect stacked switches:
Note:  
When adding a module to an existing stack, first connect the stacking cables 
and then power up the module. 
1
Plug the light grey connector of the Short Octaplane cable into the port marked 
“to upper unit” of the bottom Avaya P330 switch.
2
Plug dark grey connector of same Short Octaplane cable to the port marked “to 
lower unit” in the unit above. The connections are illustrated in Figure 4.3.
3
Repeat Steps 1 and 2 until you reach the top switch in the stack.
4
If you wish to implement stack redundancy, use the Redundant Cable to 
connect the port marked “to lower unit” on the bottom switch to the port 
marked “to upper unit” on the top switch of the stack.
5
Power up the added modules.
Caution:  
Do not cross-connect two Avaya P330 switches with two Octaplane (light-
colored) cables. If you wish to cross-connect for redundancy, use one light-colored 
Octaplane cable and one black redundancy cable. Figure 4.2 shows an incorrect 