Chapter 4        Installation and Setup
Avaya P130 User’s Guide
21
Positioning
Avaya P130 can be mounted alone or you can cascade several switches in a standard 
19-inch equipment rack in a wiring closet or equipment room. Up to 4 units can be 
cascaded in this way. When deciding where to position the unit, ensure that:
It is accessible and cables can be connected easily and according to the 
configuration rule.
Cabling is away from sources of electrical noise such as radio transmitters, 
broadcast amplifiers, power lines and fluorescent lighting fixtures.
Water or moisture cannot enter the case of the unit.
Air-flow around the unit and through the vents in the back and sides of the case 
is not restricted.
Note:  
You must use low-cost proprietary X130CK cables to interconnect cascaded 
switches.