Microsoft ES4649 Manuel D’Utilisation

Page de 674
Command Line Interface
4-56
4
clock timezone
This command sets the time zone for the switch’s internal clock.
Syntax 
clock timezone name hour hours minute minutes {before-utc | after-utc}
• name - Name of timezone, usually an acronym. (Range: 1-29 characters)
• hours - Number of hours before/after UTC. (Range: 0-13 hours)
• minutes - Number of minutes before/after UTC. (Range: 0-59 minutes)
• before-utc - Sets the local time zone before (east) of UTC.
• after-utc - Sets the local time zone after (west) of UTC.
Default Setting 
None
Command Mode 
Global Configuration
Command Usage 
This command sets the local time zone relative to the Coordinated Universal 
Time (UTC, formerly Greenwich Mean Time or GMT), based on the earth’s 
prime meridian, zero degrees longitude. To display a time corresponding to 
your local time, you must indicate the number of hours and minutes your time 
zone is east (before) or west (after) of UTC.
Example 
Related Commands
calendar set
This command sets the system clock. It may be used if there is no time server on 
your network, or if you have not configured the switch to receive signals from a time 
server.
Syntax 
calendar set hour min sec {day month year | month day year
• hour - Hour in 24-hour format. (Range: 0 - 23)
• min - Minute. (Range: 0 - 59)
• sec - Second. (Range: 0 - 59)
• day - Day of month. (Range: 1 - 31)
• month - january | february | march | april | may | june | july | august | 
september | october | november | december 
• year - Year (4-digit). (Range: 2001 - 2100)
Console(config)#clock timezone Japan hours 8 minute 0 after-UTC
Console(config)#