Moxa Technologies CP-132U Series Manuel D’Utilisation

Page de 88
 
CP-132U Series User’s Manual 
6-2 
2.  The MOXA board and driver are activated but cannot transfer (transmit/receive) 
data. 
Hardware Causes and Solutions:
 
a.  Make sure the cable wiring is connected correctly. Refer to the “Connection Cable 
and Cable Wiring” chapter for correct cable connections. 
b.  The cable or the board are probably defective. Try other ports, cables, or boards to 
verify this, or use the PComm Diagnostic utility to test the MOXA board’s and port 
conditions. If Diagnostic reports an error, replace the faulty components. 
 
Software Causes and Solutions:
 
a.  CP-132UL Series boards will check the line status (CTS) before transmitting data 
if the RTS/CTS flow control feature is set to Enable in the configuration or 
application program. Refer to the Connection Cables and Cable Wiring chapter for 
proper wiring diagrams, and check the line status of the suspected port using the 
diagnostic LED indicators on the mini tester. 
b.  The board controlling application might not be correctly written according to the 
corresponding API of the operating system. To check this problem, run another 
existing and known good application or use the utilities provided by Moxa (such 
as Pcomm Terminal emulator or HyperTerminal under Windows NT and Windows 
95/98).