Moxa Technologies EDS-405A Manuel D’Utilisation

Page de 82
EDS-408A/405A Series User’s Manual 
Featured Functions 
 
3-49
Port Event 
Warning e-mail is sent when… 
Link-on 
The port is connected to another device. 
Link-off 
The port is disconnected (e.g., the cable is pulled 
out, or the opposing device shuts down). 
Traffic-Overload 
The port’s traffic surpasses the Traffic-Threshold for 
that port (provided this setting is Enabled). 
Traffic-Threshold (%) 
Enter a nonzero number if the port’s 
Traffic-Overload setting is Enabled. 
Traffic-Duration (sec.) 
A Traffic-Overload warning is sent every 
Traffic-Duration seconds if the average 
Traffic-Threshold is surpassed during that time 
period. 
 
NOTE 
The Traffic-OverloadTraffic-Threshold (%), and Traffic-Duration (sec) Port Event items 
are related. If you Enable the Traffic-Overload event, then be sure to enter a nonzero 
Traffic-Threshold percentage, as well as a Traffic-Duration between 1 and 300 seconds. 
Override Relay Warning Settings 
Click the checkbox to override the relay warning setting temporarily. Releasing the relay output 
will allow administrators to fix any problems with the warning condition. 
Relay Warning List 
Use this table to see if any relay warnings have been issued. 
 
Using Line-Swap-Fast-Recovery 
The Line-Swap Fast Recovery function, which is enabled by default, allows the EDS to return to 
normal operation very quickly after devices are unplugged and then re-plugged into different ports. 
The recovery time is in the order of a few milliseconds. Compare this with standard commercial 
switches for which the recovery time could be in the order of several minutes. To disable the 
Line-Swap Fast Recovery function, or to re-enable the function after it has already been disabled, 
access either the Console utility’s Line-Swap recovery page, or the Web Browser interface’s 
Line-Swap fast recovery page, as shown next.