10. [RD]
This command displays the members in each 
group. 
Command Format: [RDGkUi]
k = group number (k = # from 1-9)
i = unit number (i = # from 0-9)
member = C1 - C19 (card 1 to 19) (1 to 8 for 
MT100-101 or 1 to 4 for MT100-106)
Example:
To read member data for group 5 of unit 1, send 
the [RDG5U1] command. The system will return 
feedback as C1C2C3 G5U1
11. [HELP]
This command displays all available commands 
for RS-232 control. 
7.3.SUMMARY OF COMMANDS.
1) [VER]: Receives software version
2) [C]: Receives status of the card
3) [IO]: Connects the input to the output 
4) [ON]: Turns on one or more outputs for a 
single card or a group of  cards
5) [OFF]: Turns off one or more outputs for 
a single card or a group of cards
6) [SW]: Switch (outputs the preloaded 
buffer)
7) [WR]: Groups multiple cards
8) [CLR]: Clears members of a single group 
or all groups
9) [G]: Requests group data
10) [RD]: Displays the members in each 
group.
11) [HELP]: Displays all commands
TROUBLESHOOTING GUIDE
8
We have carefully tested and have found no 
problems in the supplied MT105-110/(111);
however, we would like to offer suggestions for the 
following:
NO DISPLAY
Cause 1:
The source has a problem.
Solution: 
Check the source and make sure, that 
there is a signal present and all 
source connections are correct. If the 
source is working and there is still no 
display, see Cause 2.
Cause 2:
The card input is not selected.
Solution:
Select the card input. See RS-232 
accessible commands in section 7.If
no display is present see Cause 3.
Cause 3:
Cable connections to the destination 
are incorrect.
Solution 1:
Make sure that cables are connected 
properly. Also, make sure that the 
continuity and wiring are good. If there 
is still no display present, see Cause 
4.
Cause 4:
The display has a problem.
Solution 1:
Make sure that the display is powered. 
If there is still no display, call 
ALTINEX at (714) 990-2300.