ALTINEX MT105-111 Manuel D’Utilisation
MULTI-TASKER
13
13
10. [RD]
This command displays the members in each
group.
group.
Command Format: [RDGkUi]
k = group number (k = # from 1-9)
i = unit number (i = # from 0-9)
member = C1 - C19 (card 1 to 19) (1 to 8 for
MT100-101 or 1 to 4 for MT100-106)
MT100-101 or 1 to 4 for MT100-106)
Example:
To read member data for group 5 of unit 1, send
the [RDG5U1] command. The system will return
feedback as C1C2C3 G5U1
the [RDG5U1] command. The system will return
feedback as C1C2C3 G5U1
11. [HELP]
This command displays all available commands
for RS-232 control.
for RS-232 control.
7.3.SUMMARY OF COMMANDS.
1) [VER]: Receives software version
2) [C]: Receives status of the card
3) [IO]: Connects the input to the output
4) [ON]: Turns on one or more outputs for a
single card or a group of cards
5) [OFF]: Turns off one or more outputs for
a single card or a group of cards
6) [SW]: Switch (outputs the preloaded
buffer)
7) [WR]: Groups multiple cards
8) [CLR]: Clears members of a single group
or all groups
9) [G]: Requests group data
10) [RD]: Displays the members in each
group.
11) [HELP]: Displays all commands
TROUBLESHOOTING GUIDE
8
We have carefully tested and have found no
problems in the supplied MT105-110/(111);
however, we would like to offer suggestions for the
following:
problems in the supplied MT105-110/(111);
however, we would like to offer suggestions for the
following:
NO DISPLAY
Cause 1:
The source has a problem.
Solution:
Check the source and make sure, that
there is a signal present and all
source connections are correct. If the
source is working and there is still no
display, see Cause 2.
source connections are correct. If the
source is working and there is still no
display, see Cause 2.
Cause 2:
The card input is not selected.
Solution:
Select the card input. See RS-232
accessible commands in section 7.If
no display is present see Cause 3.
no display is present see Cause 3.
Cause 3:
Cable connections to the destination
are incorrect.
Solution 1:
Make sure that cables are connected
properly. Also, make sure that the
continuity and wiring are good. If there
is still no display present, see Cause
4.
continuity and wiring are good. If there
is still no display present, see Cause
4.
Cause 4:
The display has a problem.
Solution 1:
Make sure that the display is powered.
If there is still no display, call
ALTINEX at (714) 990-2300.
ALTINEX at (714) 990-2300.