Lenovo 6433 Manuel D’Utilisation

Page de 110
Power
 
problems
 
 
v
   
Follow
 
the
 
suggested
 
actions
 
in
 
the
 
order
 
in
 
which
 
they
 
are
 
listed
 
in
 
the
 
Action
 
column
 
until
 
the
 
problem
 
is
 
solved.
 
v
   
See
 
the
 
parts
 
listing
 
in
 
the
 
Hardware
 
Maintenance
 
Manual
 
to
 
determine
 
which
 
components
 
are
 
customer
 
replaceable
 
units
 
(CRU)
 
and
 
which
 
components
 
are
 
field
 
replaceable
 
units
 
(FRU).
 
v
   
If
 
an
 
action
 
step
 
is
 
preceded
 
by
 
“(Trained
 
service
 
technician
 
only),”
 
that
 
step
 
must
 
be
 
performed
 
only
 
by
 
a
 
trained
 
service
 
technician.
 
Symptom
 
Action
 
The
 
power-control
 
button
 
does
 
not
 
work
 
(the
 
server
 
does
 
not
 
start).
 
Note:
 
The
 
power-control
 
button
 
will
 
not
 
function
 
until
 
20
 
seconds
 
after
 
the
 
server
 
has
 
been
 
connected
 
to
 
ac
 
power.
 
1.
   
Make
 
sure
 
that
 
the
 
front-panel
 
assembly
 
power-control
 
button
 
is
 
working
 
correctly:
 
a.
   
Disconnect
 
the
 
server
 
power
 
cords.
 
b.
   
Reconnect
 
the
 
power
 
cords.
 
c.
   
Press
 
the
 
power-control
 
button.
2.
   
Make
 
sure
 
that:
 
v
   
The
 
power
 
cords
 
are
 
correctly
 
connected
 
to
 
the
 
server
 
and
 
to
 
a
 
working
 
electrical
 
outlet.
 
v
   
The
 
server
 
contains
 
the
 
correct
 
type
 
of
 
DIMMs.
 
v
   
The
 
DIMMs
 
are
 
correctly
 
seated.
 
v
   
The
 
LEDs
 
on
 
the
 
power
 
supply
 
do
 
not
 
indicate
 
a
 
problem.
 
v
   
The
 
microprocessor
 
is
 
correctly
 
installed.
3.
   
Reseat
 
the
 
following
 
components:
 
a.
   
DIMMs
 
b.
   
Power
 
supply
 
cables
 
to
 
all
 
internal
 
components
 
c.
   
Power
 
supplies
 
(hot-swap
 
models)
4.
   
Replace
 
the
 
following
 
components
 
one
 
at
 
a
 
time,
 
in
 
the
 
order
 
shown,
 
restarting
 
the
 
server
 
each
 
time:
 
a.
   
DIMMs
 
b.
   
Power
 
supplies
 
(hot-swap
 
models)
 
c.
   
(Trained
 
service
 
technician
 
only)
 
Power
 
supply
 
(non-hot
 
swap
 
models)
5.
   
If
 
you
 
just
 
installed
 
an
 
optional
 
device,
 
remove
 
it,
 
and
 
restart
 
the
 
server.
 
If
 
the
 
server
 
now
 
starts,
 
you
 
might
 
have
 
installed
 
more
 
devices
 
than
 
the
 
power
 
supply
 
supports.
 
6.
   
See
 
“Power-supply
 
LEDs”
 
and
 
“Solving
 
undetermined
 
problems”
 
in
 
the
 
Hardware
 
Maintenance
 
Manual.
 
The
 
server
 
does
 
not
 
turn
 
off.
 
1.
   
Determine
 
whether
 
you
 
are
 
using
 
an
 
Advanced
 
Configuration
 
and
 
Power
 
Management
 
(ACPI)
 
or
 
a
 
non-ACPI
 
operating
 
system.
 
If
 
you
 
are
 
using
 
a
 
non-ACPI
 
operating
 
system,
 
complete
 
the
 
following
 
steps:
 
a.
   
Press
 
Ctrl+Alt+Delete.
 
b.
   
Turn
 
off
 
the
 
server
 
by
 
holding
 
the
 
power-control
 
button
 
for
 
5
 
seconds.
 
c.
   
Restart
 
the
 
server.
 
d.
   
If
 
the
 
server
 
fails
 
POST
 
and
 
the
 
power-control
 
button
 
does
 
not
 
work,
 
disconnect
 
the
 
ac
 
power
 
cord
 
for
 
20
 
seconds;
 
then,
 
reconnect
 
the
 
ac
 
power
 
cord
 
and
 
restart
 
the
 
server.
2.
   
(Trained
 
service
 
technician
 
only)
 
If
 
the
 
problem
 
remains
 
or
 
if
 
you
 
are
 
using
 
an
 
ACPI-aware
 
operating
 
system,
 
suspect
 
the
 
system
 
board.
 
The
 
server
 
unexpectedly
 
shuts
 
down,
 
and
 
the
 
LEDs
 
on
 
the
 
front-panel
 
assembly
 
are
 
not
 
lit.
 
See
 
“Solving
 
undetermined
 
problems”
 
in
 
the
 
Hardware
 
Maintenance
 
Manual
 
.
 
 
Chapter
 
5.
 
Solving
 
problems
 
71