Lightwave Communications 3200 Manuel D’Utilisation

Page de 88
 
70
 
The tftp server must be specified by a numerical IP address.  The file path and name on 
the server is specified after the IP address. 
 
local serial connection: 
 
sys admin>> tftp /b 172.16.1.1:fdevice.bin 
 
Starting tftp download................................................. 
....................................................................... 
......................... 
 
Download complete. 
 
sys admin>> 
 
 
In the example above, the sys admin is connected through a local serial connection.  
The tftp download is performed through slot b (/b qualifier) from the tftp server at 
172.16.1.1, and the file fdevice.bin is retrieved. 
 
network session: 
 
sys admin>> tftp 172.16.1.1:fdevice.bin 
 
Starting tftp download................................................. 
....................................................................... 
.......................... 
 
Download complete. 
 
sys admin>> 
 
 
 
In the example above, the sys admin is connected through a network session.  The tftp 
download is performed through the same card to which the sys admin is connected. 
 
 
sys admin>> tftpkill 
 
 
If for some reason the tftp download must be halted, the command TFTPKILL can be 
entered at the sys admin>> prompt to stop any download in progress. This must be 
entered at the local serial connection or at a remote Sys Admin session to a network 
card other than that used by the tftp transfer. 
 
 
sys admin>> lciupdate /tftp h1 
 
 
Once a flash update file has been downloaded via tftp, it can be sent to the appropriate 
card using the LCIUPDATE command with the qualifier /TFTP.  This sends the last 
downloaded file to the card processor specified.