Expansion cards and BBU
Ê
Open the slot to be fitted (1).
Ê
Remove the slot lock by pulling the green handle upward (2), pushing the
plastic part down (3) and lifting the slot lock (4).
plastic part down (3) and lifting the slot lock (4).
Ê
Pull the removal tool out of the slot by the handle (5).
8.4.4
Removing the retaining plate
Figure 64: Removing the retaining plate from the removal tool
Ê
Lift the green movable engaging hooks (see arrows) no more than
approximately 1 mm until the retaining plate is completely released.
approximately 1 mm until the retaining plate is completely released.
V
CAUTION!
The engaging hooks may easily be damaged if too much pressure is
applied.
applied.
Ê
Take the retaining plate out and put it aside.