IBM HS40 Manuel D’Utilisation

Page de 172
001
 
COMPLETE
 
THE
 
FOLLOWING
 
STEPS
 
TO
 
PERFORM
 
THE
 
CHECKOUT
 
PROCEDURE.
  
1.
   
Turn
 
off
 
the
 
server
 
and
 
all
 
external
 
devices,
 
if
 
any
 
are
 
attached.
  
2.
   
Check
 
all
 
cables
 
and
 
power
 
cords.
  
3.
   
Set
 
all
 
display
 
controls
 
to
 
the
 
middle
 
position.
  
4.
   
Turn
 
on
 
all
 
external
 
devices.
  
5.
   
Turn
 
on
 
the
 
server.
  
6.
   
Record
 
any
 
POST
 
error
 
messages
 
that
 
are
 
displayed
 
on
 
the
 
screen.
 
If
 
an
 
error
 
is
 
displayed,
 
look
 
up
 
the
 
first
 
error
 
in
 
 
 
 
 
 
  
7.
   
Check
 
the
 
information
 
LED
 
panel
 
blade
 
error
 
LED;
 
if
 
it
 
is
 
lit,
 
see
 
 
 
 
 
 
 
 
 
 
 
  
8.
   
Check
 
the
 
system-error
 
log.
 
If
 
an
 
error
 
was
 
recorded,
 
see
 
 
 
 
 
 
 
  
9.
   
Start
 
the
 
diagnostic
 
programs.
 
10.
   
Check
 
for
 
the
 
following
 
responses:
 
v
   
One
 
beep
 
v
   
Readable
 
instructions
 
or
 
the
 
main
 
menu
002
 
DID
 
YOU
 
RECEIVE
 
BOTH
 
OF
 
THE
 
CORRECT
 
RESPONSES?
  
NO.
 
Find
 
the
 
failure
 
symptom
 
in
 
 
 
 
 
 
 
  
YES.
 
Run
 
the
 
diagnostic
 
programs.
 
If
 
necessary,
 
see
 
 
 
 
 
 
 
 
  
If
 
you
 
receive
 
an
 
error,
 
see
 
 
 
 
 
 
 
  
If
 
the
 
diagnostic
 
programs
 
were
 
completed
 
successfully
 
and
 
you
 
still
 
suspect
 
a
 
problem,
 
see
 
 
 
 
 
Diagnostic
 
tools
 
overview
 
The
 
following
 
tools
 
are
 
available
 
to
 
help
 
you
 
diagnose
 
and
 
solve
 
hardware-related
 
problems:
 
v
   
Beep
 
codes
 
and
 
error
 
messages
 
The
 
beep
 
codes
 
indicate
 
that
 
the
 
power-on
 
self-test
 
(POST)
 
or
 
the
 
baseboard
 
management
 
controller
 
(BMC)
 
have
 
detected
 
a
 
problem
 
during
 
startup.
 
Error
 
messages
 
also
 
appear
 
during
 
startup
 
if
 
POST
 
detects
 
a
 
hardware-configuration
 
problem.
 
See
 
 
 
 
 
 
for
 
more
 
information.
 
v
   
Diagnostic
 
programs
 
and
 
error
 
messages
 
Real
 
Time
 
Diagnostics
 
tests
 
the
 
major
 
components
 
of
 
the
 
BladeCenter
 
unit,
 
including
 
the
 
managemente
 
modules,
 
switch
 
modules,
 
CD-ROM
 
drive,
 
diskette
 
drive,
 
and
 
the
 
blade
 
server,
 
while
 
the
 
server
 
operating
 
system
 
is
 
running.
 
Real
 
Time
 
Diagnostics
 
can
 
either
 
be
 
plugged
 
into
 
an
 
existing
 
IBM
 
Director
 
environment
 
or
 
installed
 
without
 
IBM
 
Director
 
present.
 
For
 
documentation
 
and
 
download
 
information
 
for
 
the
 
Real
 
Time
 
Diagnostics,
 
go
 
to
 
http://www.ibm.com/servers/xseries/systems_management/xseries_sm.html.
 
Notes:
  
1.
   
As
 
of
 
the
 
date
 
of
 
this
 
document,
 
the
 
IBM
 
Director
 
CD
 
does
 
not
 
come
 
with
 
the
 
BladeCenter
 
T
 
unit.
 
If
 
you
 
have
 
the
 
BladeCenter
 
T
 
unit,
 
see
 
the
 
IBM
 
Eserver
 
BladeCenter
 
HS40
 
Type
 
8839
 
Installation
 
and
 
User’s
 
Guide
 
for
 
more
 
information.
   
22
 
BladeCenter
 
HS40
 
Type
 
8839:
 
Hardware
 
Maintenance
 
Manual
 
and
 
Troubleshooting
 
Guide