Upgrading R5si/R6si to R8r EPN and Adding Memory 
3-45
Release 5/6si to Release 8r 
3
DS1 CONV-Remoted Cabinets
The distance between the DS1 facilities and associated equipment room 
hardware and cabling is a maximum of approximately 200 circuit miles (322 km) 
for analog voice and 500 circuit miles (805 km) for digital (no analog voice 
stations).
NOTE:
These limits for DS1 remoting is the maximum distance between 
any 2 port 
networks in a Release 8r system with either direct or switched port network 
connections with a TN1654 DS1 Converter Circuit pack. 
Digital public network tie trunk facilities provide the end-to-end connectivity 
between the port networks. For either type of port network (PPN or EPN), a 
TN1654 DS1 Converter circuit pack serves as the port network interface to 
the DS1 facilities. As a PPN interface, a TN1654 DS1-CONV can reside in 
either:
A port carrier (in any port slot)
A switch-node carrier (in port slot “1” or “21”)
As an EPN interface, a TN1654 DS1 CONV can reside in an expansion control 
carrier (in any port slot).
DS1 Cabling within the Local Port Networks. 
Use the running list that 
accompanies the upgrade equipment to determine which cable connects where. 
The following paragraphs only provide conceptual information about wiring a 
DS1 Converter interface either to an expansion interface or to a switch node 
interface, not step-by-step procedures for wiring a specific Release 8r system.
NOTE:
It is important to label every cable installed. 
A cable connects each DS1 CONV either to the appropriate TN570 expansion 
interface (for a direct connection to another port network) or to the appropriate 
TN573B SN Interface (for a switched connection to another port network).
NOTE:
These cables usually connect to TN570 expansion interfaces (already 
installed) for direct connections between the new PPN and either 1 or 2 
EPNs.
On the DS1 CONV side, a 4C retainer binds this shielded cable to the DS1 CONV 
port connector. On the EI/SNI side, a 4B retainer binds the cable to the EI/SNI 
port connector. The DS1 CONV-to-EI/SNI cable also provides a piggy-back 
connector enabling subsequent access to the public network.