Emerson NET 1080T Fascicule

Page de 2
© 2008 Liebert Corporation. All rights reserved throughout the 
world. Specifications subject to change without notice.
® Liebert is a registered trademark of Liebert Corporation.
All names referred to are trademarks or registered 
trademarks of their respective owners.
IO-22002_REV0_07-08
Technical Support / Service
800-222-5877 
(Outside U.S. 614-841-6755)
upstech@emersonnetworkpower.com
Web site: www.liebert.com
United States
1050 Dearborn Drive
P.O. Box 29186
Columbus, OH 43229
F
EATURES
Indicators
Each Liebert PSS has a visual SURGE PROTECTION 
indicator
 that illuminates (green) to show that the surge 
suppressor is functioning properly.
The Liebert PSS also has an audible alarm to alert you if 
the suppression fails. Surge suppressors are often hidden 
from view behind furniture and other objects that prevent you 
from seeing the visual indicator.
Wall Mounting
If wall mounting is desired, two keyed slots are provided and 
located on the back of the surge suppressor.
T
ROUBLESHOOTING
If the Liebert PSS malfunctions during operation, check the following chart for proper adjustment. For further assistance, 
please contact your local Emerson Network Power representative.
S
PECIFICATIONS
 
Wall Mounting Detail
Rear View
Problem
Recommended Actions
The green 
GROUND 
indicator 
does not 
illuminate.
Try plugging the Liebert PSS into a different wall receptacle. 
• If the indicator illuminates, the Liebert PSS is operating properly and the first wall receptacle needs repair. Please 
contact an electrician to repair the faulty receptacle.
• If the indicator does NOT illuminate in a different receptacle:
• Your building wiring might not contain a ground conductor. In this case, the indicator light will not illuminate but 
you will still have power out of the Liebert PSS.
• The Liebert PSS may have been damaged. Please contact your supplier for any warranty return/repair 
instructions.
The green
SURGE
PROTECTION
indicator
does not
illuminate
when
powered ON.
Try plugging the Liebert PSS into a different wall receptacle.
• If the indicator illuminates, the Liebert PSS is operating properly and the first wall receptacle needs repair. Please 
contact an electrician to repair the faulty receptacle.
• If the indicator does NOT illuminate in a different receptacle:
• The Liebert PSS may have been overloaded and the internal circuit breaker may have tripped. Remove all 
loads from device and reset the circuit breaker by pushing the button back in. Replace loads one at a time.
• The Liebert PSS may have been damaged. Please contact your supplier for any warranty return/repair 
instructions.
Model Number
PRF 1080
NET 1080T
AC Power Protection
Nominal Operating Voltage 
120V
Maximum Operating Voltage 
130V
Rated Output
15A
Mode of Protection
L-N, L-G, N-G
Peak Surge Rating
72,000A
Surge Energy
1080 Joules
EMI/RFI Filtration
Yes
UL 1449 Surge Voltage Rating
330V
Network Protection
Connection Type
RJ45
Protection
2 Pair