Metrologic Instruments IS8000 Manuel D’Utilisation
33
A
PPENDIX
C
IS8000 Series Pinout Connections
D
ESCRIPTION
P
IN
S
IGNAL
1
12VDC Input Power to Scanner
2
12VDC Input Power to Scanner
3 Earth
Ground
5 Power
Ground
4 Power
Ground
Connector Type on Scanner:
DEC9P (D-Type 9-Pin Male)
DEC9P (D-Type 9-Pin Male)
6
12VDC Input Power to Scanner
7
12VDC Input Power to Scanner
8 Power
Ground
Function:
Power Port
Power Port
9 Power
Ground
D
ESCRIPTION
P
IN
S
IGNAL
1 Flip
Sense
2 Data
3 Decode
3 Decode
LED
4 Reserved
5 Proximity
5 Proximity
Detect
Connector Type on Scanner:
DEC9P (D-Type 9 Pin Male)
DEC9P (D-Type 9 Pin Male)
6 Laser/Motor
Control
7 Ground
8 Shield
8 Shield
Function:
Hand Held Port (Low Speed Option)
Hand Held Port (Low Speed Option)
9
+5VDC Power to Scanner
IS8400E/IS8400LE and IS8500E/IS8500LE Scanners Only
D
ESCRIPTION
P
IN
S
IGNAL
1 Beeper
Signal
2 N/C
3 Red
3 Red
LED
4 Power
Ground
Connector Type on Scanner
8 Pin AMP CPC Male
8 Pin AMP CPC Male
5 Green
LED
6 N/C
7 N/C
7 N/C
Function:
External Speaker Box Port
External Speaker Box Port
8 N/C
IS8400/IS8500/IS8800
IS8300