Metrologic Instruments IS1650 Manuel D’Utilisation

Page de 52
 
 
12 
I
NSTALLATION
 
 
C
ABLE 
I
NSTALLATION 
(I
NTERFACE 
S
PECIFIC
 
RS232  IS1650-14 
 
1.  Turn off the host device.  
 
2.  Plug the male 10-pin RJ45 end of 
the PowerLink cable into the 10-pin 
socket on the IS1650.  There will be 
an audible click when the connector 
lock engages. 
 
3.  Connect the 9-pin D-type connector 
of the communication cable to the 
proper COM port of the host device. 
 
4.  Plug the power supply into the 
power jack on the PowerLink cable.  
 
Check the AC input 
requirements of the power 
supply verify the voltage 
matches the AC outlet.  The 
outlet must be located near the 
equipment and be easily 
accessible. 
 
5.  Connect the power supply 
transformer to an appropriate AC 
power outlet. 
 
6.  The IS1650 will start to initialize.  All LEDs (yellow, white, and blue) will light 
for approximately two seconds then start to alternately flash.  When the 
scanner has finished initializing the LEDs will stop flashing and the unit will 
beep three times indicating that the scanner is ready for use. 
 
7.  Turn on the host device. 
 
 
 
Plugging the scanner into a port on the host system does not guarantee 
that scanned information will be communicated properly to the host 
system.  The scanner is shipped from the factory configured with default 
settings.  Please refer to the MetroSelect Single-Line Configuration 
Guide (
MLPN 
00-02544) or MetroSet2’s help files for instructions on 
changing the scanner’s configuration.  In addition, please check that the 
scanner and host system are using the same communication protocol.  
 
 
See SELV Power caution statement located on page 10 of this manual
Figure 8.