DpuScan
  
Scamax 2600 / 5000
 
Scanner Options
 
 
Illustration 5 – Scanner Properties with Links to the Patchcode Controlled Index 
Note: If the required software modules are not installed, the button and the dropdown list for the 
modes will not appear. When the scanner has the required hardware, the "Index" page is shown. 
 
 
5.2 
Terms and Definitions 
Before we go to the configuration, we will take a look on some terms often used in this text: 
 
5.2.1 Header 
The header is the data structure, 512 bytes long, that is sent along with each image from the scanner 
interface to the host. It is composed as per the following table: 
 
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 
F r o n t   # - - - - - - - - - 0  
 
18 19 20 21 22 23 24 25 26 27 88 29 30 31 32 33 34 35 36 
L e n g t h  =   - - - - - - - 0    
 
37 38 39 40 41 42 43 44 45 46 47 
L e v e l   =   - 0  
 
Page 16 of 42