Brocade Communications Systems DCX 8510-4 Manuel D’Utilisation

Page de 168
Brocade DCX 8510-4 Backbone Hardware Reference Manual
105
53-1002177-05
Brocade DCX 8510-4 chassis removal and replacement
5
NOTE
The ports and cables used in trunking groups must meet specific requirements. For a list of 
these requirements, refer to the Fabric OS Administrator’s Guide.
a. Position one of the transceivers so that the key is oriented correctly to the port and insert 
the transceiver into the port until it is firmly seated and the latching mechanism clicks.
b. Select the cable that corresponds to the port and position it so that the key (the ridge on 
one side of the cable connector) is aligned with the slot in the transceiver. Insert the cable 
into the transceiver until the latching mechanism clicks.
c. Repeat step a and step b for the remaining ports.
d. Organize the cables as required.
ATTENTION
Do not route cables in front of the air exhaust vents.
Verifying correct configuration of the fabric
Copying the command outputs from this section into a file is recommended. 
1. Create an “after” SAN profile by entering the following commands and copying the output to a 
text file named SANafter.txt:
nsShow
nsAllShow
switchShow
fabricShow
lscfg --show (if using the Virtual Fabric feature)
switch:admin> nsshow
Type Pid    COS     PortName NodeName TTL(sec)
 N    020f00;      3;10:00:00:01:73:00:29:46;10:00:00:01:73:00:29:46; na
    Fabric Port Name: 20:0f:00:60:69:90:03:f0
<output truncated>
switch:admin> nsallshow
{
 020f00 021fda 021fdc 021fe0 021fe1
5 Nx_Ports in the Fabric}
switch:admin> switchshow
switchName: rsl8-st03-dcx-01
<output truncated>
switch:admin> fabricshow
Switch ID Worldwide Name Enet IP Addr FC IP Addr Name
<output truncated>
switch:admin>lscfg --show
Created switches: 128(ds) 1 2(bs)
Port 
1
 2
 3
 4
 5
 6
7
8
9
-------------------------------------------------------------------