Brocade Communications Systems DCX 8510-4 Manuel D’Utilisation

Page de 168
136
Brocade DCX 8510-4 Backbone Hardware Reference Manual
53-1002177-05
Troubleshooting
C
All diagnostic tests are run at all supported link speeds. They might temporarily lock the transmit 
and receive speeds to a specific speed. Some diagnostic tests require interconnecting the ports to 
each other or using loopback plugs. If ports are interconnected, the media (cables and 
transceivers) at each end of the connection must be of the same type. For example, short 
wavelength media must be connected to short wavelength media, and likewise with long 
wavelength media and copper media.
For more information about diagnostic tests and how to run them, refer to the Fabric OS 
Administrator’s Guide
 and the Fabric OS Command Reference. For information about system error 
messages (errShow or errDump), refer to the Fabric OS Troubleshooting and Diagnostics Guide.
Troubleshooting
 provides a list of issues, possible causes, and recommended actions.
TABLE 26
Troubleshooting the Brocade DCX 8510-4 
Issue
Possible cause
Recommended action
Entire chassis powers off 
automatically.
Power supplies are inadequate to support the 
installed components.
Add an additional power supply.
Several or all components are not 
operating.
One or both power cables may not be 
connected to a live source.
Ensure that both power cables are connected to live 
outlets.
One or both AC power switches might be off.
Ensure that both AC power switches are on (AC 
switches light up green when on).
Serial connection is faulty or serial 
port logs have incorrect or missing 
information.
Serial cable is not connected correctly.
Ensure that the cable is firmly connected to 
workstation computer and to the Brocade DCX 
8510-4.
Terminal emulator application parameters 
are not set correctly.
Ensure that the terminal emulator application is 
configured as follows: 9600 bits per second, 8 
databits, no parity, 1 stop bit, no flow control.
Serial port might be incompatible (only 
RS-232 is supported).
Ensure that the Brocade DCX 8510-4 is connected to 
an RS-232 port. RS-423 serial ports might 
experience difficulties due to corner-case 
incompatibilities of the standards.
Pins on the serial cable or serial port might be 
damaged.
Remove the cable and inspect the pins on the cable 
and in the serial port. Do not reinstall if the pins on 
either component have any visible damage, as this 
could damage the pins on the other component. 
Replace the components as required.
CP Ethernet link speed is different 
than expected or a link cannot be 
established.
There might be a conflict with the CP Ethernet 
link speed negotiation set up by the network.
Specify the CP Ethernet link speed by typing the 
ifModeSet command. 
For more information about Ethernet connectivity to 
the Brocade DCX 8510-4, refer to the LAN guidelines 
provided through the MyBrocade Web site.
Configuration data is inaccurate or 
cannot be accessed.
Chassis was powered off/on while an WWN 
card was uninstalled or failed.
Install an operational WWN card and power the 
system off/on again.
The Brocade DCX 8510-4 was rebooted while 
an WWN card was uninstalled or failed.