Canon Model 6401 B Manuel D’Utilisation

Page de 47
Field Test Unit Software
7.3  USER  DEFINED  SCREEN  FORMAT
This  screen  format  allows  the  user  to  set  up  and  save  a  custom  designed  for-
mat  for  a  specific  application.  This  routine  is  initialised  by  pressing  the  "E"
key.  The  FTU  will  then  prompt  the  user  to  enter  in:
Offset, 
this  is  to  select   the  chosen  memory  byte  to  be  displayed  or
altered.  Up  to  12  bytes  can  be  displayed  on  the
screen  at  one  time.
If  an  offset  larger  than  11  is  chosen  then  previous  bytes
must  be  removed  to  make  room  for  the  chosen
byte.  This  feature  allows  the  user  to  skip  over  cer-
tain  bytes  and  yet  display  others.
Bytes
this  entry  is  used  with  certain  instruments  which  require  a  2
bytes  to  send  all   data  to  the  logger,  (i.e.  Hi-Res  In-
terface,  Water  Level   Instrument).  Most  raw  data  in-
struments  require  only  one  byte.  To  display  time  in
the  format  a  4  byte  input  is  required.
Formula
this  entry  allows  the  user  to  select  a  defined  formula
from   a  list  of  pre  defined  formulas  or  to  display  the
raw  logger  value.
Select  the  appropriate  formula  for  your  application  from  the  list  below
Key  Stroke 
Function
None 
Do  not  display  this  entry
None - Do not use any formula on this entry
 Red - Red thermistor formula (6507A)
Yellow  -  Yellow   thermistor  formula  (6507B) 
I
 Violet - Violet thermistor formula (6507C)
Direction  -  Use  the  wind  direction  formula
 Use the soil moisture formula (6513A)
  Full  scale  -  User  defined  full  scale  entry
Hi-Res  Entry  is  a  2’s  compliment  13  bit  value
Time - Decode the entry as a date and time
If formulas RYVS have been selected then the  FTU  will respond with a
prompt  for  the  user  to  enter  the  value  of  the  reference  resistor  used  with  the
transducer.
If  the  formulas  FH  have  been  selected  then  the  FTU  will  prompt  with  a  line
“Min value?”. The minimum desired vaIue  for the scaling should then be
Section 7.  FTUC  COMMANDS 