Miele DA 249-4 Manuel D’Utilisation
Total connected load* . . . . . . . . . 240 W
– Fan motor* . . . . . . . . . . . . . . . . 200 W
– Hob lighting . . . . . . . . . . . . . 2 x 20 W
– Fan motor* . . . . . . . . . . . . . . . . 200 W
– Hob lighting . . . . . . . . . . . . . 2 x 20 W
Halogen lamps
Osram type 44890 WFL, 20 W
Osram type 44890 WFL, 20 W
Voltage . . . . . . . . . . . . . . . . . . . . 230 V
Frequency . . . . . . . . . . . . . . . . . . 50 Hz
Fuse rating GB . . . . . . . . . . . . . . . . . 3 A
AUS, NZ:
Plug rating . . . . . . . . . . . . . . . . . . . 10 A
Test marks . . . . . . . . . . Electrical safety
. . . . . . . . . . . . . . . . . . . . . . C-Tick Mark
Electrically suppressed
according to AS/NZS 1044
according to AS/NZS 1044
Electrical cable length . . . . . . . . . 1.5 m
Weight
DA 249-4 . . . . . . . . . . . . . . . . . . 22.5 kg
DA 249-4 EXT . . . . . . . . . . . . . . 19.5 kg
DA 249-4 Alu . . . . . . . . . . . . . . . 22.5 kg
DA 249-4 Alu EXT . . . . . . . . . . . 19.5 kg
DA 249-4 . . . . . . . . . . . . . . . . . . 22.5 kg
DA 249-4 EXT . . . . . . . . . . . . . . 19.5 kg
DA 249-4 Alu . . . . . . . . . . . . . . . 22.5 kg
DA 249-4 Alu EXT . . . . . . . . . . . 19.5 kg
Fan performance*
Extraction power according to
EN 61591
EN 61591
Extraction system
C 150 mm:
Level I . . . . . . . . . . . . . . . . . . . 200 m
3
/h
Level II. . . . . . . . . . . . . . . . . . . 300 m
3
/h
Level III . . . . . . . . . . . . . . . . . . 400 m
3
/h
Level IV Intensive Setting . . . . 640 m
3
/h
Extraction system
C 125 mm:
Level I . . . . . . . . . . . . . . . . . . . 180 m
3
/h
Level II. . . . . . . . . . . . . . . . . . . 280 m
3
/h
Level III . . . . . . . . . . . . . . . . . . 380 m
3
/h
Level IV Intensive Setting . . . . 580 m
3
/h
Recirculation with charcoal filter:
Level I . . . . . . . . . . . . . . . . . . . 150 m
3
/h
Level II. . . . . . . . . . . . . . . . . . . 210 m
3
/h
Level III . . . . . . . . . . . . . . . . . . 330 m
3
/h
Level IV Intensive Setting . . . . 490 m
3
/h
Special accessory for recirculation
mode:
mode:
– Conversion kit DUW 10
– Miele charcoal filter DKF 9-1
* For EXT models, the connected load
and extraction power will depend on
the type of external motor fitted.
and extraction power will depend on
the type of external motor fitted.
EXT models:
Length of connection cable to external
motor. . . . . . . . . . . . . . . . . . . . . . . 1.9 m
Length of connection cable to external
motor. . . . . . . . . . . . . . . . . . . . . . . 1.9 m
Technical data