89 
 
 
 
 
 
 
 
Troubleshooting
 
Code 
Description 
CDh 
Target position missed; position controller went past desired position without 
achieving objective. MEDIUM ERROR. 
CEh 
Failure to achieve ATF locking within time-out period. MEDIUM ERROR. 
CFh 
Failure to reach the target point on tape. MEDIUM ERROR. 
D0h 
Unexpected physical BOM encountered. 
D1h 
Failure to position. HARDWARE ERROR. 
D2h 
Servo command time-out. HARDWARE ERROR. 
D3h 
Drum took too long to reach speed. HARDWARE ERROR. 
D4h 
Failure to process one servo event before servo processor sent next event. 
HARDWARE ERROR. 
D5h 
Too long between successive servo message events. HARDWARE ERROR. 
D6h 
Unexpected position counter. 
D7h 
Calculated supply-reel diameter is suspect. HARDWARE ERROR. 
D8h 
Tape not available for use. HARDWARE ERROR. 
D9h 
Tape is threaded; command received which requires no tape to be threaded. 
HARDWARE ERROR. 
DAh 
No cartridge in drive; cartridge is expected. HARDWARE ERROR. 
DBh 
Cartridge present; no cartridge expected. HARDWARE ERROR. 
DCh 
Time-out when finding Absolute Frame Count of append point. MEDIUM ERROR. 
DDh 
Initialization error. HARDWARE ERROR. 
DEh 
Buffer controller detected underflow. HARDWARE ERROR. 
DFh 
Buffer controller detected overflow. HARDWARE ERROR. 
E0h 
Buffer controller detected parity error. HARDWARE ERROR. 
E1h 
Overflow in servo message to main 68000 processor. HARDWARE ERROR. 
E2h 
System log on tape is unreadable. MEDIUM ERROR. 
E3h 
Tape either blank or completely unreadable. BLANK CHECK. 
E4h 
Tape not in valid DDS format. MEDIUM ERROR, with Additional Sense of 3002h 
(cannot read media, incompatible format). 
E5h 
Parity error in reading track checksums out of buffer RAM. HARDWARE ERROR. 
E6h 
Failure in position controller’s internal state machine. HARDWARE ERROR. 
E7h 
Unable to find target position on tape. MEDIUM ERROR. 
EEh 
Failed to measure tracking calculation; not enough samples to calibrate time-
tracking properly. 
F0h 
Device command rejected because a previous command failed. HARDWARE 
ERROR. 
F1h 
Invalid command sequence. HARDWARE ERROR. 
F2h 
Invalid tape length. 