Leica DISTO D810 Manuel D’Utilisation

Page de 44
Leica DISTO
TM
 D810 touch 799093a
38
EN
Message Codes
If the message Error does not disappear 
after switching on the device repeatedly, 
contact the dealer.
If the message InFo appears with a number, 
press the Clear button and observe the 
following instructions:
Care
Clean the device with a damp, soft cloth.
Never immerse the device in water.
Never use aggressive cleaning agents or 
solvents.
Warranty
Lifetime Manufacturer's Warranty
Warranty coverage for the entire usage time 
of the product according to Leica Geosys-
tems International Limited Warranty. Free of 
charge repair or replacement for all products 
that suffer defects as a result of faults in mate-
rials or manufacturing, for the entire life of 
the product.
3 Years No Cost
Guaranteed service should the product 
become defective and require servicing 
under normal  conditions of use, as described 
in the user manual, at no additional charge.
To receive the "3 years no cost" period, the 
product must be registered at www.leica-
geosystems.com/registration within 8 weeks 
of the purchase date. If the product is not 
registered, a "2 years no cost" period applies. 
Functions
Distance measuring
yes
Min/Max measuring
yes
Permanent measuring
yes
Stake-out
yes
Addition/Subtraction
yes
Area
yes
Triangle area
yes
Volume
yes
Trapezium
yes
Painter function (area with partial 
measurem.)
yes
Pythagoras
2-point, 3-point
Smart Horizontal Mode / 
Indirect height
yes
Height-profile measurement
yes
Level
yes
Sloped objects
yes
Height tracking
yes
Memory
yes
Beep
yes
Illuminated colour display
yes
Multifunctional endpiece
yes
Pointfinder (Viewscreen) 
4x zoom, OV
Bluetooth
®
 Smart
yes
Personalized Favorites
yes
Timer
yes
Long Range Mode
yes
Calculator
yes
Photo/Screenshot
yes
Compass
yes
Gallery with USB download
yes
Diameter
yes
Width
yes
Area from Photo
yes
No.
Cause
Correction
156
Transverse tilt greater 
than 10°
Hold the instrument 
without any transverse tilt.
162
Calibration mistake
Make sure, the device is 
placed on a absolutely 
horizontal and flat surface. 
Repeat the calibration 
procedure. If the mistake 
still occurs, contact your 
dealer.
204
Calculation error
Perform measurement 
again.
240
Data transfer error
Repeat procedure.
252
Temperature too high Let device cool down.
253
Temperature too low Warm device up.
255
Received signal too 
weak, measuring time 
too long
Change target surface 
(e.g. white paper).
256
Received signal too 
high
Change target surface 
(e.g. white paper).
257
Too much back-
ground light
Shadow target area.
258
Measurement outside 
of measuring range
Correct range.
260
Laser beam inter-
rupted
Repeat measurement.