Heath Zenith UT-9250-WH Manuel D’Utilisation

Page de 42
-10-
598-1290-02
Adjustments Continued . . .
 Loosen the two thumb screws. Estimate the direction to aim the sensor and
tighten the thumbscrews just enough to hold the sensor in place.
 
NOTE: The top screw allows the sensor to rotate side to side. The bottom
screw allows the sensor to rotate up and down.
 Walk  through  the  coverage  area  noting  where  you  are  when  the  lights
turn on (also, the LED will flash several times when motion is detected).
Loosen the thumbscrews and readjust the sensor as necessary. Tighten the
thumbscrews (finger tight) when you are satisfied with the coverage direc-
tion.
Keep the sensor at least 1 inch (25 mm) from lamps and keep the 
controls facing downward.
 Adjust RANGE as needed to increase or decrease the range. Too much
sensitivity may cause false triggering in some environments.
 For maximum range, the sensor must be aiming straight out.
 Set the amount of TIME (1, 5, or 20 minutes) you want the lights to stay
on after motion is detected at night.
 Release the tab on metal door to allow door to close.
Expected Coverage
The sensor is less sensitive to motion directly to-
wards it, most sensitive to motion across its field
of view.
When mounted 8 feet (2.4 m) from the ground, you
may expect the range shown below. If mounted
much higher the sensor may miss objects near the
ground. If mounted much lower the sensor range
may be reduced.
Sensor
  Least Sensitive 
Most Sensitive
Motion
Motion
Aim Sensor Down 
for Short Coverage
Aim Sensor Out for 
Long Coverage
Maximum Range
(Sensor aiming straight out)
 8 ft.
(2.4 m)
70 ft. (21.0 m)  100 ft. (0.5 m)
With RANGE 
With RANGE 
Set to MAX 
Boosted