Mount the Light Control
  Align the light control cover plate and cover plate 
gasket and the junction box. Insert and tighten the 
mounting screws.
  If not installed on a weatherproof box or if an adaptor 
plate is used, 
caulk the wall plate and mounting 
surface with silicone weather sealant.
The halogen light must be 
mounted horizontally (+/- 4°).
MOUNT HORIZONTALLY
Bulb Installation and Re-lamping
  When re-lamping, 
turn power off and let the fixture 
cool.
Remove glass cover and remove the old bulb by 
pushing the bulb towards the right until the left side 
of the bulb is clear of the left socket.
  To insert the new bulb, push the bulb into the right 
socket  so  the  bulb  fits  completely  into  the  left 
socket.
  Check that the bulb is seated properly.
  Re-install the glass cover.
For proper operation and safety, the light fixture must 
be above the sensor and the sensor head must be 
rotated so that the controls are on the bottom.
 CAUTION: To Avoid Fire Or Burn Hazards:
•  Allow fixture to cool before touching. The bulb and 
the fixture operate at high temperatures.
•  Keep fixture at least 2" (51 mm) from combustible ma-
terials. Do not aim at objects closer than 3 ft. (1 m).
•  Re-lamp with type T halogen, 500 W max., 120 VAC 
lamp only.