Chauvet DMX512 Manuel D’Utilisation

Page de 32
 
COLORdash
™ Par 
 
User Manual  
29
 
9/4/2008 12:09 PM
 
COLORDASH™ PARService Maintenance Guide 
Symptom(s) 
Possible Solution(s) 
1 or more LED’s are not 
illuminating 
Clean the fixture regularly to avoid any such failure. This fixture is convection 
cooled, which means that if the surface is kept clean and free of debris, then 
proper cooling will be allowed to occur 
 
An LED may have failed, resulting in an open circuit. In this event, all of the 
red, green, or blue in a single module will no longer illuminate. This does not 
mean that all of the LEDs have failed, but the circuit is wired in series.  
 
An LED may have failed, resulting in a short circuit. In this event, only the 
single LED which has failed will no longer function. This does not mean that all 
of the LEDs have failed, but the circuit is wired in series. 
 
-Note: In the event of LED failure, a replacement LED PCB assembly may be 
purchased directly from Chauvet               Part#: 
P222-M1LEDP
 
1 or more LED’s are producing 
very low output 
Check that the lens assembly is installed properly. If the lens assembly is not 
aligned properly over the LEDs, then they will not project fully 
-See section on Lens Assembly Installation 
   
-Note: In the event of LED failure, a replacement LED PCB assembly may be 
purchased directly from Chauvet             Part#: 
P222-M1LEDP
 
Breaker/Fuse keeps blowing 
Check total load placed on the electrical circuit 
 
Check for a short in the electrical wiring: internal and/or external 
Device has no power 
Check device’s fuse (internal) 
 
Check for power on Mains 
 
Check cable connections The 
COLORdash™ PAR cables must be firmly 
connected for operation 
 
-Note: In the event of autoswitching transformer failure, the unit can be sent in 
for repair; however, a replacement part can be ordered directly from Chauvet        
                                                                  Part#: P140-M1ELTR 
Fixture is not responding to DMX 
Check Control Panel settings for correct addressing 
 
Check DMX cables 
 
Check polarity switch settings on the controller 
 
Check cable connections 
 
Call service technician 
 
-Note: In the event of Master PCB failure, a replacement PCB can be ordered 
directly from Chauvet                                 Part#: 
P170-MINIPD
 
Loss of signal 
Use only DMX cables 
 
Install terminator 
 
Note: Keep DMX cables separated from power cables or black lights 
COLOR-CON Controller does 
not function, or does not function 
properly 
Make sure connector is firmly connected to device 
 
The 
COLORdash™ PAR fixture must be in the correct mode in order to properly 
respond to the COLOR-CON controller. The correct mode is 
“SLAVE” in the 
onboard Control Panel 
Stand alone operation 
This fixture has built-in, automatic programs that may be triggered from the 
onboard Control Panel 
 
If you still have a problem after trying the above solutions, please contact CHAUVET 
Technical Support at the location on page 28.