Hobart ML-130193 LXeR Manuel D’Utilisation

Page de 32
– 11 –
PRIMING CHEMICAL PUMPS
When a chemical becomes empty, the priming operation starts automatically the next time the machine 
is turned on or a wash cycle is started. Note that the initial prime time for all pumps (Detergent, Rinse 
Agent, and Sanitizer) is 60 seconds. If the chemical is not sensed within 60 seconds, the add chemical 
indicator will flash. After the chemical is sensed, the indicator in the display turns off; and the pump 
continues to prime for 10 seconds to allow the chemicals to reach the machine. If all chemicals are 
empty, the sanitizer will prime first followed by detergent. Only one chemical pump will run at a time.
If chemicals are not sensed after three consecutive priming operations, the add chemical indicator will 
flash and priming is cancelled. The next time a wash cycle is started, the add chemical indicator will 
continue to flash. Verify that the chemical bottles are not empty and that the delivery tube standpipes 
are inserted completely to the bottom of the containers.
The priming operation can be reset by turning the dishwasher off, then back on.
If the chemical bottles are not empty and the delivery tube standpipes are inserted correctly, then the 
chemical sensor or pumps may have malfunctioned; contact your local Hobart Service Office.