GE GSD6200 Manuel D’Utilisation

Page de 44
– 16 –
sure that the protruding ribs from the escutch-
eon fit inside the stainless steel front opening.
Adjust the position of the outer panel up or
down, left or right to center the panel with the
escutcheon.
6. Once the panel is centered, install the 2 screws
in the bottom of the panel to connect the stain-
less steel outer panel to the hinge arms.   Re-
check to make sure the escutcheon ribs are
protruding through the panel opening.
7. While holding the outer panel against the door
assembly, slowly open the door to about 45
degrees open so that the remaining 8 panel
screws can be installed (4 screws on each
side).
Door Interlock Switch
The door interlock switch opens the L1 circuit and
Neutral circuit when the door is open.
Caution: After removing the screws from the
escutcheon keypad assembly, the assembly is
still attached to the control module by 2 ribbon
cables. Dropping or rough handling of the
escutcheon will cause the ribbon cable to tear, and
the entire escutcheon keypad assembly will need
to be replaced.
1. Remove the escutcheon keypad assembly (see
Escutcheon Keypad Assembly
).
2. Remove 2 screws and the switch from the door.
3. Carefully remove the cover from the switch and
unplug the blade connectors.
Note: The wire color code is on the switch cover.
P0003703
2 Screws
2 Screws
P0003705
BX
BW
BW
BX
NO COM
J2-7
J2-8
J1-3
J1-1
NO
N
L1
COM
WX
DOOR
WR
DOOR
DOOR INTERLOCK SWITCH