Hoshizaki JWE-24000CUA-L-25B Manuel D’Utilisation

Page de 79
44
 
Conveyor Speed 
Too high. 
Adjust to medium or 
low. 
Continue
Detergent 
No supply. 
See “III.C.5. No or 
Inadequate 
Detergent/Rinse Aid 
Supply.”
Insufficient supply. 
Refill or adjust 
detergent feeder. 
Unspecified detergent 
used.
Use specified 
detergent only. 
Check input/output 
and repair or replace. 
Control output error. 
Reset manually. 
Overheat thermostat 
tripped.
Replace.
 
Defective.
 
Replace.
Magnetic contactor 
defective.
Wash Tank Water 
Dirty. 
Drain wash tank and 
supply fresh hot water.
Temperature too low. 
Raise setting or see 
“Heater Not 
Energized”.
Temperature will not 
rise.
Reset overheat 
thermostat. 
Heater Not Energized 
Voltage 
Too low. 
Call electrician.