Hoshizaki JWE-2400CUA-R-25B Manuel D’Utilisation

Page de 79
10
4. If BT WLF/S fails, BT BUWLF/S assumes control. If BT BUWLF/S remains closed for 1 
minute, o1 or o2 error appears in the display. For details, see "III.B. Error Codes."
5. The wash/rinse start switch is inactive during the auto fi ll cycle.
2. Ready Cycle (Unit Inactive)
"READY" lamp and "RINSE TEMP." or "WASH TEMP." lamp on.
WT WLS closed. After a rinse cycle, RPM de-energizes, and the "READY" lamp comes on.
WTH energizes when WT water temperature is at the wash temperature setpoint or 
lower. WTH de-energizes when WT water temperature is 5°F (3°C) above the setpoint. 
For details, see "Wash Temperature Setpoint" (service menu item 04) in "II.F.7.b) Service 
Menu Chart."
BTH energizes when BT water temperature is 3°F (2°C) below the rinse temperature 
setpoint or lower. BTH de-energizes when BT water temperature reaches the setpoint. 
WV energizes/de-energizes when BT WLF/S opens/closes. For details, see "Rinse 
Temperature Setpoint" (service menu item 05) in "II.F.7.b) Service Menu Chart."
Note:
1. The thermistors control WT and BT water temperatures.
2. If one of the thermistors has an open or short circuit, WTH or BTH de-energizes and an 
error code appears in the display.
3. WTH and BTH are controlled regardless of SPS operation.
3. Wash Cycle/Rinse Cycle
"WASH" lamp and "RINSE TEMP." or "WASH TEMP." lamp on.
When a rack is loaded from the wash compartment entrance and the wash start switch 
closes, WPM energizes, power is supplied to DFT and the "WASH" lamp comes on. WPM 
draws water from WT and sends it through the wash spray arms. The upper spray arm 
WPM starts fi rst, followed by the lower spray arm WPM. Then, the conveyor starts to move 
the rack. After the wash start switch opens and the extended wash cycle time (factory 
default: 30 seconds) has expired, WPM de-energizes and power is cut to DFT. For details, 
see "Extended Wash Cycle Time" (service menu item 01) in "II.F.7.b) Service Menu Chart."
When the rinse start switch closes, RPM energizes and power is supplied to RFT. RPM 
draws water from BT and sends it through the rinse spray arms. Rinse aid is fed into the 
rinse water line and sprayed from the rinse spray arms together with rinse water. Any 
excess water in WT drains through the overfl ow pipe. After the rinse start switch opens 
and the extended rinse cycle time (factory default: 15 seconds) has expired, RPM de-
energizes, power is cut to RFT, the "WASH" lamp goes off and the "READY" lamp comes 
on. For details, see "Extended Rinse Cycle Time" (service menu item 02) in "II.F.7.b) 
Service Menu Chart."
After both WPM and RPM de-energize, the conveyor stops. If SP is opened during 
operation, SPS opens, WPM and RPM de-energize and the conveyor stops. If the wash/
rinse start switch is closed when SPS closes, WPM and RPM energize and the conveyor 
restarts.
Note:
1. If WT WLS opens after WPM energizes, WPM de-energizes and RPM energizes for 
the supplementary fi ll cycle time (factory default: 450 seconds) to supply hot water into