h) ROM/RAM Error (H5)
• If a ROM/RAM error is detected, the unit shuts down, "H5" appears in the display, and the 
buzzer sounds.
• After replacing the failed component, the alarm resets.
• See the chart below for possible causes and remedies.
i) EEPROM Error (H6)
• If an EEPROM error is detected, the unit shuts down, "H6" appears in the display, and the 
buzzer sounds.
• After replacing the failed component, the alarm resets.
• See the chart below for possible causes and remedies.
Note:  See “IV.I. Removal and Replacement of Control Board or Operation Board.”
 
 
 
 
 
 
 
 
 
 
Control Board 
Defective. 
Replace.
ROM/RAM on control board fails. 
H 5 
Code Error 
Item Possible 
Cause 
Remedy 
Unit stops. 
Operation 
 
 
 
 
 
 
 
 
 
 
 
EEPROM on control board fails. 
H 6 
Code Error 
Item Possible 
Cause 
Remedy 
Unit stops. 
Operation 
Control Board 
Defective. 
Replace.