Hoshizaki JWE-2400CUA-R-25B Manuel D’Utilisation

Page de 79
40
m) Booster Tank Water Level Safety Error (b2)
• If the booster tank water level safety fl oat switch opens after the booster tank water level 
fl oat switch closes, the unit shuts down, "b2" appears in the display, and the buzzer sounds.
• To reset, use the "ON/OFF" button to turn the unit off and then back on.

Booster tank water level safety float switch 
opens after booster tank water level float switch 
closes.
b 2 
Code Error 
Item Possible 
Cause 
Remedy 
Unit stops
 
Operation 
Flow rate too low. 
Readjust. 
Water supply pressure 
too low. 
Readjust. 
Water Heater 
Strainer 
Filter clogged. 
Clean.
Filter clogged. 
Clean.
Defective. 
Replace.
Water Valve 
Open circuit. 
Repair or replace. 
Control Board 
Defective. 
Replace.
Connector not properly 
connected.
Reconnect.
Booster Tank Water 
Level Safety Float 
Switch
Open circuit or 
connector not properly 
connected.
Repair or replace. 
Sticking. 
Check and clean. See 
“III.D. Float Switch 
Check and Cleaning.
Defective. 
Replace.
Rinse Spray Arm 
Disconnected or water 
leaks from joint. 
Reconnect.
Defective. 
Replace.
Clogged. 
Clean.
Rinse Water Level 
Insufficient water 
supply. 
Readjust. 
Pressure Reducing 
Valve