Setting the temperature
• Press button
 
for 1 second. The temperature display flashes.
•  To increase the temperature (warmer): press button
.
• To reduce the temperature (colder): press button
.
• Press button
 again.
The desired temperature setting is saved.
Switching the appliance on and off
Connect the appliance to the mains - the display reads OFF.
Switching the appliance on: Keep the ON/OFF button 
 
pressed for approx. 5 seconds - the display reads ON.
No alarm is displayed or sounded when the appliance is switched 
on for the first time.
If the appliance is disconnected from the mains for a long time after 
it has been switched on for the first time and if the temperature
inside the appliance rises above the upper alarm limit, this will 
be detected as a fault by the electronic control system (HACCP 
appears in the display).
When the appliance is switched on again, this display must be 
reset as shown below.
Press button 
.
Press 
 + 
 for 5 seconds. The display will read 
.
The HACCP LED will now light up permanently.
Press 
 for 5 seconds.
The electronic control system will automatically switch back to 
normal operating mode.
Switching  the  appliance  off:  Keep the ON/OFF button 
 
pressed for approx. 5 seconds - the display reads OFF.
Door open alarm
When the door is opened, the LED   and the temperature display 
begin to flash.
When the door has been left open for more than 60 seconds, the 
LED   begins to flash, and 
 and the temperature indication 
flash alternately in the display.
The audible warning signal sounds (unless the audible warning 
signal function has been deactivated).
If the door has to stay open for longer in order to insert items to be 
cooled, cancel the audible warning signal by pressing button 
.
Audible warning signal 
The audible warning signal will sound in certain alarm events. It 
can be cancelled by pressing button 
.
Operating and control elements
1
ON/OFF
 button (to switch the appliance on and off)
2
Selection buttons
3
Set
 button (Enter)
4
Audible warning
on/off button
5
Button for calling up stored alarm events
6
Temperature display
Control elements
 
Compressor is running
 
LED flashing - refrigeration unit switches on after a delay. The
compressor will start automatically after the pressure in the 
refrigerant circuit has equalised. 
 
Fan is running
 
Appliance is defrosting
AUX
  Temperature display via product sensor is activated
 
Alarm function
 
If 
 appears in the display, the appliance has a fault. Consult 
your nearest customer service point.
HACCP
  (Hazard Analysis Critical Control Point)
 
The HACCP display means that the power supply and 
interior temperature of the appliance are recorded.
If HACCP flashes in the display, there has either been a
power failure or the temperature in the appliance exceeded 
the permissible range.
Electrical connection
Only operate the appliance with alternating current (AC).
The permissible voltage and frequency are indicated on the type 
plate. The position of the type plate is shown in the section entitled 
Description of the appliance.
The socket must be properly earthed and protected by a fuse.
The tripping current of the fuse must be between 10 A and 16 A.
The socket must not be situated behind the appli-
ance and must be easily accessible.
Do not connect the appliance using an exten-
sion cable or extension socket.
Do not use stand-alone inverters (conversion
of direct current to alternating/three-phase cur-
rent) or energy-saving plugs. Risk of damage 
to the electronic control system!