KitchenAid W10526088A Manuel D’Utilisation
9
3. Remove foam strip from literature packing. Remove backing
from foam strip. Apply foam strip adhesive-side down along
the left and right sides of the cooktop trim.
the left and right sides of the cooktop trim.
NOTE: The foam strip helps the cooktop sit flat on uneven
counters and avoids damage to the countertop surface.
counters and avoids damage to the countertop surface.
4. Using 2 or more people, turn cooktop right side up.
Install Optional Backguard
48" (121.9 cm) models and all models with a grill may require a
backguard. See “Cabinet Dimensions” in the “Location
Requirements” section for installation requirements. See the
“Tools and Parts” section for information on ordering.
backguard. See “Cabinet Dimensions” in the “Location
Requirements” section for installation requirements. See the
“Tools and Parts” section for information on ordering.
Remove island trim and attach backguard using 6 screws; insert
3 from the front and 3 from the back (9" [22.9 cm] backguard
shown).
3 from the front and 3 from the back (9" [22.9 cm] backguard
shown).
Make Gas Connection
To Assemble Pressure Regulator:
1. Using 2 or more people, stand the cooktop on its side or
back.
2. Connect the flexible stainless steel connector to the pressure
regulator using a
¹⁄₂" male pipe thread adapter.
A combination of pipe fittings must be used to connect the
cooktop to the existing gas line. Shown following is a typical
connection. Your connection may be different, according to
the supply line type, size and location.
cooktop to the existing gas line. Shown following is a typical
connection. Your connection may be different, according to
the supply line type, size and location.
A. Cooktop base
B. Foam strip
B. Foam strip
C. Cooktop
A
B
C
A. Gas pressure regulator
B. Regulator - Must be installed with arrow pointing up to
B. Regulator - Must be installed with arrow pointing up to
cooktop bottom
C. Adapter - Must have
¹⁄₂
" male pipe thread
D. CSA approved flexible stainless steel gas supply line
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 14" (36 cm) water
column.
gas pressure does not exceed 14" (36 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A
B
D
C