Fisher & Paykel OR60 Manuel D’Utilisation

Page de 32
12
Installation instructions
Adjusting the minimum burner setting 
Check whether the flame spreads to all burner ports when the burner is lit with the gas tap set to 
the minimum position. If some ports do not light, increase the minimum gas rate setting. 
Check whether the burner remains lit even when the gas tap is turned quickly from the 
maximum to the minimum position. If the burner does not remain lit, increase the minimum gas 
rate setting.
The procedure for adjusting the minimum gas rate setting is described below. 
 
 Turn on the burner 
 
 Turn the tap to the MINIMUM position 
 
 Take off the knob 
 
 With a small flat screwdriver turn the screw to the correct regulation.
Note: for LPG gas, the regulation screw is normally tightened up.
Table for the choice of the injectors 
Natural gas
LPG gas
Test Point Pressure [kPa]
1.0
2.75
BURNER
Injector
Orifice Dia.
[mm]
Gas 
Consumption
[MJ/h]
Injector
Orifice Dia.
[mm]
Gas 
Consumption
[MJ/h]
Auxiliary
0.85
3.60
0.53
3.60
Semi-rapid
1.12
6.30
0.70
6.30
Wok
1.65
13.30
0.95
11.90
Figure 10 Adjusting the minimum burner setting