Lincoln Series 1200 Manuel D’Utilisation

Page de 112
Impinger I -–1000 Series Service Manual - International 
52 
Temp. display 
inaccurate, erratic, or 
inoperative 
Time/Temp. Display 
Perform the power supply check, the thermistor 
probe check, and then perform the time/temp. 
simulator test. Refer to page 72 for instructions. 
Remember, when using the time/temp. simulator, 
remove all leads from the back of the time/temp. 
display except the 3 power leads. After completion 
of the test, and if re-installing time/temp. display 
back in the oven, the dip switches must be reset for 
oven operation, and the time/temp. display must be 
recalibrated. If readings are not achieved, replace 
display. 
 
Perform all checks as in the above evaluation. If 
the time check is okay, refer to the next section. 
Conveyor Drive  
(Stepper) Motor 
Check to see if the conveyor drive (stepper) motor 
is running. If motor is not running refer to 
"Conveyor will not run" on page 50. 
Magnet 
Check to insure that the magnet (cemented to shaft 
of conveyor drive (stepper) motor) has not been 
damaged, or come loose from motor shaft. Replace 
as needed. 
Hall Effect Sensor 
Check for any physical damage to Hall Effect 
Sensor(mounted on conveyor drive(stepper)motor.) 
Check all wiring and connections for damage. 
Time Display 
inaccurate, erratic or 
inoperative 
Conveyor Drive 
(Stepper) Control 
Check all connections for tightness or proper 
location and check all wiring for visible damage. 
Replace as needed. If there is still no time display, 
wire in (temporarily) a new conveyor drive control. 
If there is still no time display, reconnect original 
conveyor drive control. Replace Hall Effect Sensor.