Lincoln Series 1200 Manuel D’Utilisation

Page de 112
Impinger I -–1000 Series Service Manual - International 
56 
 
   
MOTOR
CENTRIFUGAL 
SWITCH
RED
RED
24 VAC TO 
IGNITION CONTROL
TO GROUND TERMINAL 
ON IGNITION CONTROL
GROUND
24 VAC
120 VAC
 
GREEN
WHITE
BLACK
(BUTTSPLICE CONNECTORS PROVIDED FOR 120 VAC POWER SUPPLY)
WIRING DIAGRAM 
 
BURNER BLOWER ASSEMBLY 
WITH RELAY REMOVED
TRANSFORMER 
P/N 369531 
(WHEN USING OLD 
TRANSFORMER, 120 
VAC LEADS ARE BLACK. 
WIRE TERMINALS ARE 
PROVIDED.)
 
   
BLOWER WHEEL, BURNER 
 
 
This is part of the burner blower motor assembly. 
 
 
TO REMOVE THE BLOWER WHEEL FOR PERIODIC CLEANING: 
 
1. 
Shut off power at main breaker. 
2. 
Remove control panel top and front cover. 
3. 
Remove air shutter held by 3 screws. 
4. 
Loosen set screw on blower wheel hub and pull straight out. 
5. 
Reassemble in reverse order. 
NOTE:  
There is no critical placement of the blower wheel on the motor shaft. Just back as 
far as it will go and then spin the blower to be sure it is not rubbing. 
 
 
AIR PRESSURE SWITCH 
 
1. 
Shut off power at main breaker. 
2. 
Remove front control compartment cover. 
3. 
Remove air switch cover plate. 
4. 
Disconnect wiring and mark for reassembly. 
5. 
Loosen 2 screws and remove air switch. 
6. 
Disconnect 1/4" air tube. 
7. 
Reassemble in reverse order. 
8. 
Turn on power and calibrate air switch as follows:  
Turn adjusting screw counter clockwise to full out position.  
Turn main fan and heat switch on. 
Turn adjusting screw clockwise until heat shuts off.  
Turn adjusting screw counterclockwise 1/4 turn and unit should heat. 
NOTE: 
Test as follows:  
Oven must be tested in heated condition.  
Remove main fan fuse. Main fan should shut down, deactivating air switch causing  
heat to shut off in approximately 5 to 25 seconds.