Lincoln Series 1000 Manuel D’Utilisation

Page de 112
Impinger I -–1000 Series Service Manual - International 
26 
TROUBLESHOOTING GUIDE 1000 & 1200  / GAS OVENS 
 
SYMPTOM 
POSSIBLE CAUSE 
EVALUATION 
Incoming Power Supply 
Check breakers/ Reset if required / Call Power Co. 
if needed. 
(Export Ovens) 
For some export ovens, there is a control circuit 
step-down transformer. This transformer steps 
down supply voltage to 120 VAC. If main fan will 
not run, the secondary of this transformer must be 
checked for 120 VAC output. Check specific oven 
model schematic for circuit location. 
Oven Fan Fuse(s) 
Check and/or Replace 
Fuse Holder 
Check and/or Replace 
Fan Switch 
Check continuity between switch terminals. 
Main Relay 
Check continuity to 120 VAC coil. Check for power 
to relay coil (120 VAC). Check for 208/240 VAC to 
relay terminals. Visually check for contact pull-in. 
Fan Motor 
Check for opens, shorts, or grounds. WITH 
POWER OFF: Turn Fan Blade to check for locked 
rotor. 
Oven fan will not run 
 
NOTE: 
Capacitor 
Check for opens, shorts, or grounds. 
No Main Fan Cool 
Down 
Cool Down Thermostat 
Check cool down thermostat (thermostat closes at 
160°F and opens at 140°F). Check for power (120 
VAC) at cool down thermostat. With the cool down 
thermostat pre-heated, check for continuity. If 
switch is open, replace. 
No Control Box 
Cooling(For ovens 
equipped with Control 
Box Cooling Fan)  
 
 
 
NOTE
Main Fan Relay 
 
 
 
(Export Ovens) 
Axial Cooling Fan 
Check for power to Main Fan Relay. Visually check 
for contact pull in.  
 
 
(For ovens equipped with a control circuit step-
down transformer, the supply voltage for the 
cooling fan is 240 VAC.) 
WITH POWER OFF: check for locked rotor. Check 
for power (120 VAC) to cooling fan. If 120 VAC is 
present at the fan motor and the fan does not run, 
replace fan assembly. 
Incoming Power Supply 
Check breakers/Reset if needed. Check for 
incoming power (120 VAC)at cooling fan 
thermostat. 
Cooling Fan Thermostat 
Check cooling fan thermostat (thermostat closes at 
120°F and opens at 100°F). With cooling fan 
thermostat pre-heated, check for continuity. If 
switch is open, replace. 
No automatic control 
box cooling (For ovens 
equipped with control 
box cooling fan) 
Axial Cooling Fan 
Check for 120 VAC to cooling fan, if present and 
fan does not run, replace fan. 
Control box cooling fan 
continues to run 
Cooling Fan Thermostat 
See
 
"Cooling Fan Thermostat" 
Check for 120 VAC to primary 
of transformer. Check for 24 
VAC from secondary of 
transformer. If there is 
primary voltage, but no 
secondary voltage, replace 
transformer. 
Check for adequate gas supply to oven. 
Manual Gas Shut-off Valve 
Check to see that manual shut-off valve is open. 
Fan Switch 
Check to see that fan switch is "on". 
Transformer, 24 VAC 
Main Oven Fan 
Check if main oven fan is operating. If not, refer to 
"Oven fan will not run". Page 26.