TROUBLESHOOTING GUIDE 1000 & 1200 SERIES / ELECTRIC OVENS 
 
SYMPTOM
 
POSSIBLE CAUSE
 
EVALUATION
 
Incoming Power Supply 
Check breakers/Reset if required/ Call Power Co. if 
needed. 
(Export Ovens) 
For some export ovens, there is a control circuit 
step-down transformer. This transformer steps 
down supply voltage to 120 VAC. If main fan will 
not run, the secondary of this transformer must be 
checked for 120 VAC output. Check specific oven 
model schematic for circuit location. 
Oven Fan Fuse(s) 
Check and/or Replace 
Fuse Holder 
Check and/or Replace 
Fan Switch 
Check continuity between switch terminals. 
Main Relay 
Check continuity to 120 VAC coil. Check for power 
to the relay coil (120 VAC). Check for 208/220/240 
VAC to relay terminals. Visually check for contact 
pull-in 
Fan Motor 
Check for opens, shorts, or grounds. WITH POWER 
OFF: Turn Fan Blade to check for locked rotor. 
Oven fan will not run 
 
NOTE: 
Capacitor 
Check for opens, shorts, or grounds. 
No Main Fan Cool 
Down 
Cool Down Thermostat 
Check cool down thermostat (thermostat closes at 
160°F and opens at 140°F). Check for power (120 
VAC) at cool down thermostat. With cool down 
thermostat pre-heated, check for continuity. If 
switch is open, replace. 
Main Fan
 
Relay 
Check for power to main fan relay. Visually check 
for contact pull in. 
No control box cooling 
Axial Cooling Fan 
WITH POWER OFF: turn the fan blade to check for 
locked rotor. Check for power (120 VAC) to cooling 
fan. If 120 VAC is present at the fan motor and the 
fan does not run, replace fan assembly. 
Main Oven Fan 
Check if main oven fan is operating. If not, refer to 
"Oven fan will not run." 
Heat Switch 
Check for continuity between switch terminals with 
switch on. Replace if defective. 
Air Pressure Switch 
Check for 120 VAC on both sides of switch. If 
voltage present on one side only, check for air tube 
blockage, adjust air switch. If above fails, replace 
air pressure switch. 
Hi Limit Thermostat 
Terminals are normally closed. If open, reset and 
test oven for proper operation. If thermostat will not 
hold for maximum oven temperature, and oven is 
not exceeding temperature dial setting, replace 
thermostat (rated at 190°F). 
Hi Limit Thermostat  
(Model 1032) 
Terminals are normally closed. If open, reset and 
test oven for proper operation. If thermostat will not 
hold for maximum oven temperature, and oven is 
not exceeding temperature dial setting. Replace the 
thermostat. Check for proper location of sensing 
bulb in its spring holder. If hi-limit is still tripping, 
replace (rated for 368°C). 
3 Amp Temperature Control 
Fuse 
Check and/or Replace 
Oven will not heat 
 
 
 
 
 
 
 
 
 
 
 
 
NOTE: 
Fuseholder 
Check and/or replace.