Impinger I -–1000 Series Service Manual - International 
increase or decrease as the DC voltage from the board increases or decreases 
respectively. As the motor turns, it drives both the reducer gearbox and the Tach. 
Generator. The Tach. Generator is a DC voltage generator, which supplies a voltage 
to the DC motor control board and is used as a reference for maintaining a constant 
conveyor speed. 
TlME/TEMP DISPLAY 
The Time/Temp. Display is energized when the Fan Switch is closed, supplying 120 
VAC  to the primary of the 12.6 volt Transformer. The secondary output of the 
transformer, normally 13 to 14 VAC (depending on input), with a center tap is 
supplied to terminals 1,2, and 3 of the Time/Temp Display. The center tap is terminal 
2. The display works on a balanced input and center tap voltage to each leg must be 
1,2 the total reading. 
The speed side of the Time/Temp. Display uses a slotted disc (cemented to tach. 
coupling) to break the infra-red light beam of the optical switch (mounted on gear 
motor) producing electrical pulses that are transmitted to the display. The display 
converts these pulses into a read-out of minutes and seconds. 
The temperature portion of the display uses a Thermistor Probe to sense oven 
temperature. The thermistor outputs a resistance proportional to the oven 
temperature. This resistance is then converted by the display into a temperature 
reading. 
 
SEQUENCE OF OPERATIONS 1028 / 1029 / 1228 / 1229 
 
MODEL 1028 - 380Y/220 VAC - 50 HZ - 3 PHASE 
MODEL 1029 - 415Y/240 VAC - 50 HZ - 3 PHASE 
MODEL 1228 - 380Y/220 VAC - 50 HZ - 3 PHASE - DUAL BELT 
MODEL 1229 - 415Y/240 VAC - 50 HZ - 3 PHASE - DUAL BELT 
 
POWER SUPPLY 
Electrical Power to be supplied to the Oven by a five conductor service. 
Black conductor is Hot 
Red conductor is Hot 
Orange conductor is Hot 
White conductor is Dedicated Neutral 
Green conductor is Ground 
 
MAIN FAN CIRCUIT 
Electrical power is permanently supplied through 3, 50A fuses to the normally open 
contacts of the Mercury Contactor. Power is also supplied through 1, 10A fuse to the 
normally open contact of the Main Fan Relay, through a 1A Fuse to the normally 
open Double Pole Main Fan Switch, and to the normally open Cool-Down 
Thermostat (thermostat closes at 160°F and opens at 140°F.) Closing the Main Fan 
Switch supplies 220 or 240 VAC to the primary of the control circuit Step Down 
Transformer. (The transformer steps the voltage down to 120 VAC for the control 
circuit.) 120 VAC is supplied to the coil of the Main Fan Relay. The coil of the relay is 
energized, the normally open contacts close, energizing the Main Fan Motor. Closing 
the Main Fan Switch also supplies power to the 12.6 VAC Transformer, the Control 
Box Cooling Fan, and the Heat and Conveyor Switches. 
TRANSFORMER (12.6 
VAC) 
Upon closure of the Fan Switch, 120 VAC is supplied to the primary of the 12.6 VAC 
Transformer. The Transformer steps the voltage down to 12.6 VAC (normally 13 to 
14 VAC) with a center tap, and supplies power to the Time/Temp. Display. The 
voltage from each leg of the Transformer's secondary to the center tap should be 
one half of the secondary voltage. 
HEAT CIRCUIT 
Closing the Fan Switch and the normally open Heat Switch supplies 120 VAC 
through the normally open Air Pressure Switch, and the normally closed Hi-Limit 
Thermostat (manually re-settable, opens at 190°F) and, the 3A Fuse, to the L1 
terminal of the Temperature Control Board, the coil of the Mercury Contactor, and to 
the Heat Indicator Light. 
TEMPERATURE 
CONTROL 
When the Heat Switch is closed, 120 VAC is supplied to the Temperature Control. 
The Temperature Control Potentiometer (2.5K ohm) is adjusted to desired 
temperature. The Thermocouple will provide varying millivolts to the Temperature 
Controller. The Temperature Controller switches the L 2  line of the Contactor coils at 
intermittent intervals to maintain desired temperatures.