Conveyor Drive(Stepper) 
Motor 
Check the drive sprocket on motor output shaft to 
insure that it is tight.  Check motor windings 
measurement should be approximately 2 ohms. 
Terminals 1-5, 2-6, 3-7, 4-8. WITH POWER OFF: 
Turn the motor shaft to check for jammed gear box. 
If motor shaft will not turn, replace conveyor 
drive(stepper) motor. 
12 VAC Power Supply 
(Transformer) 
Measure the transformer primary for a nominal 120 
VAC input, if voltage is not present, trace wiring 
back to the oven fan switch. Measure the 
secondary output, which will normally be 12-15 
VAC. Voltage across terminals 1 and 3 on the 
time/temp. display should read 12-15 VAC. 
Terminals 1-2 and 2-3 should be 1/2 the voltage 
reading 1 to 3. If the above secondary readings are 
not achieved, replace transformer. 
Time/Temp. Display 
inoperative 
Time/Temp. Display 
If proper voltage is present at terminal 1,2, and 3 
on time/temp. display, but the display is not lighted, 
recheck all connections for tightness. If time/temp. 
display is still not operating, replace the time/temp. 
display. 
NOTE:  Time/temp displays 
use two types of temperature 
sensor Thermistor Probe - 2 
yellow wires.  Thermocouple 
Probe - 1 red & one white 
wire 
Place your pyrometer thermocouple into the center 
between finger T2 and T3 in the oven. Disconnect 
the yellow tipped thermistor leads from the 
time/temp. terminals 9 and 10. Measure the 
resistance of the thermistor probe. 
Thermistor Probe 
See chart on page 72 for proper resistance 
readings. Inspect the thermistor bulb for its proper 
location in its spring holder. Check for short in 
leads where they enter the sensor bulb. Also check 
each thermistor lead for short to ground. 
Thermocouple Probe 
Place your pyrometer thermocouple into the center 
between fingers T2 and T3 in the oven. Connect 
temperature meter to thermocouple at terminals 9 
& 10 on back of the time/temp display.  (Be sure to 
maintain proper polarity on thermocouple 
connections.)  Compare actual oven temperature 
with the reading at the time/temp display.  If the 
temperature readings match, recalibrate or replace 
time/temp display. If the readings do not match, 
replace thermocouple probe. 
Temp. Display out or 
inaccurate 
Power Supply 
If a strange or unusual behavior is experienced, 
such as a rolling of numbers, or lock-up at a given 
number, first check for a display circuit lock-up. 
This may be caused by a voltage spike or surge in 
the incoming power lines. To eliminate this 
condition, remove power from time/temp. display by 
shutting off the main fan switch for 15 seconds. 
This should eliminate the problem. If this does not 
solve the problem, it may becoming in through the 
Commercial power lines. Suggest that customer 
contact their power company for evaluation.