Lincoln 1200 Manuel D’Utilisation

Page de 20
Impinger I – 1000 Series Ops Manual 
****NOTE: For proper operation, the gas valve 
requires a nominal inlet pressure of 7 inches H
2
column for natural gas and 11 inches of H
2
O column 
for L.P. gas.  A minimum inlet pressure of 1.0 inch of 
H
2
O above the manifold setting (NAT. manifold 3.5” 
H
2
O, L.P. manifold 10” H
2
O) must be maintained with 
no pressure drop from the no load to full load 
condition.  The maximum inlet pressure must be 
maintained at or below ½ PSIG (14.5 inches H
2
column).  Refer to the chart on the left for pressure 
conversions. 
IMPINGER
®
 CONVEYOR OVENS – MODEL SERIES 1400 
 
 
UTILITY SPECIFICATIONS REQUIRED – ELECTRIC 
 
Model 
Energy 
Power 
Voltage 
Current 
Phase 
Hz 
Recommended Electrical 
Specifications 
Agency 
Listing 
***1421-xxx-E 
Electric 
27 kW 
400/230 VAC 
40 Amps 
50 Hz 
5 Wires, 3 Poles 
1N-1G 
F-G 
1452 
Electric 
27 kW 
120/208 VAC 
80 Amps 
60 Hz 
5 Wires, 3 Poles 
1N-1G 
A-B-D-F 
1453 
Electric 
27 kW 
120/240 VAC 
70 Amps 
60 Hz 
5 Wires, 3 Poles 
1N-1G 
A-B-D-F 
1454 
Electric 
27 kW 
380/220 VAC 
41 Amps 
50 Hz 
5 Wires, 3 Poles 
1N-1G 
1455 
Electric 
27 kW 
415/240 VAC 
38 Amps 
50 Hz 
5 Wires, 3 Poles 
1N-1G 
 
 
UTILITY SPECIFICATIONS REQUIRED – GAS 
 
Model 
Energy 
Power 
Voltage 
Current 
Phase 
Frequency 
Recommended 
Electrical 
Specification 
Gas 
Agency 
Listing 
***1433-xxx-E 
Nat. Gas 
35 kW 
230 VAC 
3 Amps 
50 Hz 
3 Wires, 1 Pole 
1N-1G 
35 kW/hr at 17.4 
mB H
2
O column**** 
F-G 
***1434-xxx-E 
L.P. Gas 
35 kW 
230 VAC 
3 Amps 
50 Hz 
3 Wires, 1 Pole 
1N–1G 
35 kW/hr at 27.4 
mB H
2
O column**** 
F-G 
1450 
Nat. Gas 
120,000 
BTU 
120 VAC 
5 Amps 
60 Hz 
3 Wires, 1 Pole 
1N-1G 
120,000 BTU at 7 
inches H2O column**** 
A-D-F 
1451 
L.P. Gas 
120,000 
BTU 
120 VAC 
5 Amps 
60 Hz 
3 Wires, 1 Pole 
1N-1G 
120,000 BTU at 11 
inches H2O column****
 
A-F  
1456 
Nat. Gas 
120,000 
BTU 
220/240 
VAC 
5 Amps 
50 Hz 
3 Wires, 1 Pole 
1N-1G 
120,000 BTU at 7 
inches H2O column**** 
E-F 
1457 
L.P. Gas 
120,000 
BTU 
220/240 
VAC 
5 Amps 
50 Hz 
3 Wires, 1 Pole 
1N-1G 
120,000 BTU at 11 
inches H2O column****
 
E-F 
 
 
 
B 
H 
 
Agency 
Listing 
CSA 
UL 
 
MEA 
AGA* 
NSF 
CE 
 
 
Electrical Supply for Australia: 
Single Phase: 240VAC, 50Hz / 20 Amp: one neutral & one earth/ground. 
Three Phase: 240/415 VAC / 20 Amp; three active, one neutral & one earth/ground. 
 
* AGA Australian Gas Association 
 
** In Australia, use a 10 Amp General Purpose Outlet 
*** Reference Model Key 
 
 
 
 
All ovens require separate service and dedicated neutral. 
 
GAS PRESSURE CONVERSION CHART 
Inches of 
Water Column 
KPa 
m-Bar 
Millimeters of 
Water Column 
 
3.5 
4.5 
10 
10.5 
11 
14 
14.5 
 
0.87 
1.12 
1.74 
2.48 
2.61 
2.73 
3.48 
3.61 
 
8.70 
11.2 
17.40 
24.87 
26.11 
27.36 
34.81 
36.05 
 
88.9 
114.3 
177.8 
254.0 
266.7 
279.4 
355.6 
368.3