Lincoln 1634-000-EA Manuel D’Utilisation

Page de 32
Low Profile – 1600 Advantage Series Service Manual – International
 
 
SEQUENCE OF OPERATIONS 
 
 
MODEL 1633-000-EA   230 VAC   50HZ   NATURAL GAS  
MODEL 1634-000-EA   230 VAC   50HZ   L.P. GAS 
 
 
POWER SUPPLY 
Electrical power to be supplied to the oven by a three conductor service. 
 
Brown conductor is hot  
Blue conductor is neutral. 
Green conductor is ground. 
 
 
 
CONTROL BOX 
AUTO COOL DOWN 
 
When the temperature in either one of the control boxes reaches 120
°
±
3
°
 (49
°
±
 1.7
°
 ) , the cooling fan 
thermostats will  switch power to the cooling fans . The thermostats will interrupt power to the cooling fans when 
the temperature falls to 100
°
±
 3
°
 (37
°
±
 1.7
°
 ) 
 
 
MAIN FAN CIRCUIT 
 
Line voltage is permanently supplied to a normally open contact of the oven power switch. Line voltage is 
permanently supplied to the two normally open cooling fan thermostats, a normally open contact of the oven 
power relay. Closing the oven power switch supplies line voltage to oven power relay, its contacts now close, 
supplying line voltage to the two main fan motors and the two burner circuits. Closing the oven power switch also 
supplies line voltage to the control box cooling fans, the temp. display, and the conveyor circuit. 
 
 
BURNER CIRCUIT 
 
NOTE: This oven utilizes two complete burner/ temperature control systems. The sequence of operations is the 
same for each system. 
Closing the main fan switch supplies line voltage, through the oven power relay,  through a three amp. fuse, 
through the gas pressure switch, through the main fan air pressure switch through the oven cavity hi-limit 
thermostat, to the ignition control. The combustion motor is energized. The normally open combustion air switch 
closes upon sensing air pressure. After a pre-purge period of between 30 and 60 seconds, the ignition 
transformer and the main gas valve are energized. Ignition should now occur. 
 
 
TEMPERATURE CONTROL 
 
Closing the oven power switch supplies line voltage, through the oven power relay,  through a three amp. fuse, 
through the gas pressure switch, through the main fan air pressure switch through the oven cavity hi-limit 
thermostat, to the temperature control board. The 1.0K temperature pot. is adjusted to desired temperature. The 
thermocouple will provide varying millivolts to the temperature control. The temperature control supplies line 
voltage to the solenoid valve at intermittent intervals to maintain desired temperature. 
 
 
 
CONVEYOR DRIVE 
 
Closing the oven power switch supplies line voltage, through the oven power relay, through the electromagnetic 
filter to the conveyor control. AC volts are converted to DC volts and are supplied to the conveyor motor at 
terminals A+ and A-.